Protocol for a prospective, controlled, cross-sectional, diagnostic accuracy study to evaluate the specificity and sensitivity of ambulatory monitoring systems in the prompt detection of hypoxia and during movement.
Areia, Carlos; Vollam, Sarah; Piper, Philippa; King, Elizabeth; Ede, Jody; Young, Louise; Santos, Mauro; Pimentel, Marco A F; Roman, Cristian; Harford, Mirae; Shah, Akshay; Gustafson, Owen; Rowland, Matthew; Tarassenko, Lionel; Watkinson, Peter J.
Afiliación
  • Areia C; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK carlos.morgadoareia@ndcn.ox.ac.uk.
  • Vollam S; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
  • Piper P; Adult Intensive Care Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, Oxfordshire, UK.
  • King E; Adult Intensive Care Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, Oxfordshire, UK.
  • Ede J; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
  • Young L; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
  • Santos M; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, Oxfordshire, UK.
  • Pimentel MAF; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, Oxfordshire, UK.
  • Roman C; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, Oxfordshire, UK.
  • Harford M; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
  • Shah A; Radcliffe Department of Medicine, University of Oxford, Oxford, Oxfordshire, UK.
  • Gustafson O; Adult Intensive Care Unit, Oxford University Hospitals NHS Foundation Trust, Oxford, Oxfordshire, UK.
  • Rowland M; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
  • Tarassenko L; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, Oxfordshire, UK.
  • Watkinson PJ; Critical Care Research Group, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
BMJ Open ; 10(1): e034404, 2020 01 12.
Article en En | MEDLINE | ID: mdl-31932393
ABSTRACT

INTRODUCTION:

Automated continuous ambulatory monitoring may provide an alternative to intermittent manual vital signs monitoring. This has the potential to improve frequency of measurements, timely escalation of care and patient safety. However, a major barrier to the implementation of these wearable devices in the ward environment is their uncertain reliability, efficiency and data fidelity. The purpose of this study is to test performance of selected devices in a simulated clinical setting including during movement and low levels of peripheral oxygen saturation. METHODS AND

ANALYSIS:

This is a single centre, prospective, controlled, cross-sectional, diagnostic accuracy study to determine the specificity and sensitivity of currently available ambulatory vital signs monitoring equipment in the detection of hypoxia and the effect of movement on data acquisition. We will recruit up to 45 healthy volunteers who will attend a single study visit; starting with a movement phase and followed by the hypoxia exposure phase where we will gradually decrease saturation levels down to 80%. We will simultaneously test one chest patch, one wrist worn only and three wrist worn with finger probe devices against 'clinical standard 'and 'gold standard' references. We will measure peripheral oxygen saturations, pulse rate, heart rate and respiratory rate continuously and arterial blood gases intermittently throughout the study. ETHICS AND DISSEMINATION This study has received ethical approval by the East of Scotland Research Ethics Service REC 2 (19/ES/0008). The results will be broadly distributed through conference presentations and peer-reviewed publications. TRIAL REGISTRATION NUMBER ISRCTN61535692 registered on 10/06/2019.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Monitoreo Ambulatorio / Signos Vitales / Dispositivos Electrónicos Vestibles / Hipoxia / Movimiento Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: BMJ Open Año: 2020 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Monitoreo Ambulatorio / Signos Vitales / Dispositivos Electrónicos Vestibles / Hipoxia / Movimiento Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: BMJ Open Año: 2020 Tipo del documento: Article País de afiliación: Reino Unido