Your browser doesn't support javascript.
loading
Comparison of two pore sizes of LAE442 scaffolds and their effect on degradation and osseointegration behavior in the rabbit model.
Augustin, Julia; Feichtner, Franziska; Waselau, Anja-Christina; Julmi, Stefan; Klose, Christian; Wriggers, Peter; Maier, Hans Jürgen; Meyer-Lindenberg, Andrea.
Afiliación
  • Augustin J; Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-Universität, Munich, Germany.
  • Feichtner F; Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-Universität, Munich, Germany.
  • Waselau AC; Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-Universität, Munich, Germany.
  • Julmi S; Institut für Werkstoffkunde, Leibniz Universität Hannover, An der Universität 2, Garbsen, Germany.
  • Klose C; Institut für Werkstoffkunde, Leibniz Universität Hannover, An der Universität 2, Garbsen, Germany.
  • Wriggers P; Institute of Continuum Mechanics, Leibniz Universität Hannover, Hannover, Germany.
  • Maier HJ; Institut für Werkstoffkunde, Leibniz Universität Hannover, An der Universität 2, Garbsen, Germany.
  • Meyer-Lindenberg A; Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-Universität, Munich, Germany.
J Biomed Mater Res B Appl Biomater ; 108(7): 2776-2788, 2020 10.
Article en En | MEDLINE | ID: mdl-32170913
ABSTRACT
The magnesium alloy LAE442 emerged as a possible bioresorbable bone substitute over a decade ago. In the present study, using the investment casting process, scaffolds of the Magnesium (Mg) alloy LAE442 with two different and defined pore sizes, which had on average a diameter of 400 µm (p400) and 500 µm (p500), were investigated to evaluate degradation and osseointegration in comparison to a ß-TCP control group. Open-pored scaffolds were implanted in both greater trochanter of rabbits. Ten scaffolds per time group (6, 12, 24, and 36 weeks) and type were analyzed by clinical, radiographic and µ-CT examinations (2D and 3D). None of the scaffolds caused adverse reactions. LAE442 p400 and p500 developed moderate gas accumulation due to the Mg associated in vivo corrosion, which decreased from week 20 for both pore sizes. After 36 weeks, p400 and p500 showed volume decreases of 15.9 and 11.1%, respectively, with homogeneous degradation, whereas ß-TCP lost 74.6% of its initial volume. Compared to p400, osseointegration for p500 was significantly better at week 2 postsurgery due to more frequent bone-scaffold contacts, higher number of trabeculae and higher bone volume in the surrounding area. No further significant differences between the two pore sizes became apparent. However, p500 was close to the values of ß-TCP in terms of bone volume and trabecular number in the scaffold environment, suggesting better osseointegration for the larger pore size.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Ensayo de Materiales / Oseointegración / Sustitutos de Huesos / Aleaciones Límite: Animals Idioma: En Revista: J Biomed Mater Res B Appl Biomater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2020 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Ensayo de Materiales / Oseointegración / Sustitutos de Huesos / Aleaciones Límite: Animals Idioma: En Revista: J Biomed Mater Res B Appl Biomater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2020 Tipo del documento: Article País de afiliación: Alemania