Your browser doesn't support javascript.
loading
Creation and Testing of a Deep Learning Algorithm to Automatically Identify and Label Vessels, Nerves, Tendons, and Bones on Cross-sectional Point-of-Care Ultrasound Scans for Peripheral Intravenous Catheter Placement by Novices.
Blaivas, Michael; Arntfield, Robert; White, Matthew.
Afiliación
  • Blaivas M; University of South Carolina School of Medicine, Columbia, South Carolina, USA.
  • Arntfield R; Department of Emergency Medicine, St Francis Hospital, Columbus, Georgia USA.
  • White M; Department of Critical Care Medicine, Western University, London, Ontario, Canada.
J Ultrasound Med ; 39(9): 1721-1727, 2020 Sep.
Article en En | MEDLINE | ID: mdl-32181922
ABSTRACT

OBJECTIVES:

We sought to create a deep learning (DL) algorithm to identify vessels, bones, nerves, and tendons on transverse upper extremity (UE) ultrasound (US) images to enable providers new to US-guided peripheral vascular access to identify anatomy.

METHODS:

We used publicly available DL architecture (YOLOv3) and deidentified transverse US videos of the UE for algorithm development. Vessels, bones, tendons, and nerves were labeled with bounding boxes. A total of 203,966 images were generated from videos, with corresponding label box coordinates in a YOLOv3 format. Training accuracy, losses, and learning curves were tracked. As a final real-world test, 50 randomly selected images from unrelated UE US videos were used to test the DL algorithm. Four different versions of the YOLOv3 algorithm were tested with varied amounts of training and sensitivity settings. The same 50 images were labeled by 2 blinded point-of-care ultrasound (POCUS) experts. The area under the curve (AUC) was calculated for the DL algorithm and POCUS expert performance.

RESULTS:

The algorithm outperformed POCUS experts in detection of all structures in the UE, with an AUC of 0.78 versus 0.69 and 0.71, respectively. When considering vessels, only one of the POCUS experts attained an AUC of 0.85, just ahead of the DL algorithm, with an AUC of 0.83.

CONCLUSIONS:

Our DL algorithm proved accurate at identifying 4 common structures on cross-sectional US imaging of the UE, which would allow novice POCUS providers to more confidently and accurately target vessels for cannulation, avoiding other structures. Overall, the algorithm outperformed 2 blinded POCUS experts.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sistemas de Atención de Punto / Aprendizaje Profundo Tipo de estudio: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Ultrasound Med Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sistemas de Atención de Punto / Aprendizaje Profundo Tipo de estudio: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Ultrasound Med Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos