ABSTRACT
Objectives:
Re-do aortic valve surgery carries a higher mortality and morbidity compared with first time aortic valve replacement (AVR) and often requires concomitant complex procedures. Transcatheter aortic valve replacement (TAVR) is an option for selective patients. The aim of this study is to present our experience with re-do aortic valve procedures and give an insight into the characteristics of these patients and their outcomes.Methods:
Retrospective review of 80 consecutive re-do aortic valve procedures.Results:
Mean patients' age was 51.80±18.73 years. Aortic regurgitation (AR) was present in 51 (65.4%) patients and aortic stenosis (AS) in 38 (48.7%). Indications for reoperation were infective endocarditis (IE) (23.8%), bioprosthetic degeneration (12.5%), mechanical valve dysfunction (5%), paravalvular leak (6.2%), patient-prosthesis mismatch (3.8%), native valve disease (25%), aortic aneurysm, pseudoaneurysm and dissection (35%), aortic root/homograft degeneration (27.5%). Forty-one (51.2%) patients underwent re-do AVR, 39 (48.8%) re-do complex aortic valve surgery (28 root, 23 ascending aorta and 6 hemiarch procedures) and 37.5% concomitant procedures. A bioprosthesis was implanted in 43.8%, a mechanical valve in 37.5%, a composite graft in 2.5%, a Biovalsalva graft in 6.2% and a homograft in 10% of patients. In-hospital mortality was 3.8% and incidence of major complications was low.Conclusions:
A significant proportion of patients were young (61%<60 y), required complex aortic procedures (49%) or presented with contraindications for TAVR (mechanical valve, AR, IE, proximal aortic disease, need for concomitant surgery). Re-do aortic surgery remains the only treatment for such challenging cases and can be performed with acceptable mortality and morbidity in a specialised aortic centre.Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Válvula Aórtica
/
Insuficiencia de la Válvula Aórtica
/
Estenosis de la Válvula Aórtica
/
Complicaciones Posoperatorias
/
Implantación de Prótesis de Válvulas Cardíacas
/
Reemplazo de la Válvula Aórtica Transcatéter
Tipo de estudio:
Etiology_studies
/
Observational_studies
/
Risk_factors_studies
Límite:
Aged80
Idioma:
En
Revista:
Open Heart
Año:
2020
Tipo del documento:
Article
País de afiliación:
Reino Unido