Your browser doesn't support javascript.
loading
Analysis of the human chorionic gonadotropin protein at the intact level by HILIC-MS and comparison with RPLC-MS.
Camperi, Julien; Combès, Audrey; Fournier, Thierry; Pichon, Valerie; Delaunay, Nathalie.
Afiliación
  • Camperi J; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, UMR CBI 8231 ESPCI Paris - CNRS, PSL University, 75005, Paris, France.
  • Combès A; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, UMR CBI 8231 ESPCI Paris - CNRS, PSL University, 75005, Paris, France.
  • Fournier T; Laboratory of Physiopathology and Pharmacotoxicology of the Human Placenta, UMR-S 1139 Inserm - University Paris Descartes, Sorbonne Paris Cité, 75270, Paris, France.
  • Pichon V; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, UMR CBI 8231 ESPCI Paris - CNRS, PSL University, 75005, Paris, France.
  • Delaunay N; Sorbonne Université, 75006, Paris, France.
Anal Bioanal Chem ; 412(18): 4423-4432, 2020 Jul.
Article en En | MEDLINE | ID: mdl-32377867
ABSTRACT
In the present work, the human chorionic gonadotropin (hCG) hormone was characterized for the first time by hydrophilic interaction liquid chromatography (HILIC) coupled to high-resolution (HR) quadrupole/time-of-flight (qTOF) mass spectrometry (MS) at the intact level. This heterodimeric protein, consisting of two subunits (hCGα and hCGß), possesses 8 potential glycosylation sites leading to a high number of glycoforms and has a molecular weight of about 35 kDa. The HILIC conditions optimized in a first paper but using UV detection were applied here with MS for the analysis of two hCG-based drugs, a recombinant hCG and a hCG isolated from the urine of pregnant women. An amide column (150 × 2.1 mm, 2.6 µm, 150 Å), a mobile phase composed of acetonitrile and water both containing 0.1% of trifluoroacetic acid, and a temperature of 60 °C were used. The gradient was from 85 to 40% ACN in 30 min. The use of TFA that had been shown to be necessary for the separation of glycoforms caused, as expected, an ion suppression effect in MS that was partially overcome by increasing the amount of protein injected (2 µL at 1 mg mL-1) and reducing the detection m/z range (from 1500 to 300). These conditions allowed the detection of different glycoforms of hCGα. The performance of the HILIC-HRMS method was compared with that previously obtained in RPLC-HRMS in terms of the number of detected glycoforms, selectivity, and sensitivity. The complementarity and orthogonality of the HILIC and RP modes for the analysis of hCG at the intact level were demonstrated.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hormonas Glicoproteicas de Subunidad alfa / Gonadotropina Coriónica Límite: Female / Humans / Pregnancy Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hormonas Glicoproteicas de Subunidad alfa / Gonadotropina Coriónica Límite: Female / Humans / Pregnancy Idioma: En Revista: Anal Bioanal Chem Año: 2020 Tipo del documento: Article País de afiliación: Francia