Diaphragm Atrophy During Pediatric Acute Respiratory Failure Is Associated With Prolonged Noninvasive Ventilation Requirement Following Extubation.
Glau, Christie L; Conlon, Thomas W; Himebauch, Adam S; Yehya, Nadir; Weiss, Scott L; Berg, Robert A; Nishisaki, Akira.
Afiliación
  • Glau CL; All authors: Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA.
Pediatr Crit Care Med ; 21(9): e672-e678, 2020 09.
Article en En | MEDLINE | ID: mdl-32433439
ABSTRACT

OBJECTIVES:

Diaphragm atrophy is evident during invasive ventilation for pediatric acute respiratory failure, but with unknown significance. We hypothesized that diaphragm atrophy in pediatric acute respiratory failure is associated with prolonged noninvasive positive pressure ventilation following extubation.

DESIGN:

Prospective observational study.

SETTING:

Single-center academic PICU. PATIENTS Invasively ventilated children with acute respiratory failure.

INTERVENTIONS:

Diaphragm ultrasound was performed within 36 hours after intubation and repeated within 48 hours preceding extubation. Rapid shallow breathing index at 15 and 30 minutes of a spontaneous breathing trial and negative inspiratory force were collected in a subset of patients concurrently with the ultrasound measurements. MEASUREMENTS AND MAIN

RESULTS:

Diaphragm thickness at end-expiration was measured to assess for diaphragm atrophy during mechanical ventilation. Percentage change in diaphragm thickness at end-expiration was defined as baseline diaphragm thickness at end-expiration minus final, preextubation diaphragm thickness at end-expiration divided by baseline diaphragm thickness at end-expiration. The primary outcome measure was duration of noninvasive positive pressure ventilation following extubation with prolonged use defined as noninvasive positive pressure ventilation use for greater than 24 hours postextubation. Among 56 children, 47 (median age, 15.5 mo; interquartile range, 6-53 mo) had diaphragm thickness at end-expiration measured within 48 hours prior to extubation. Fourteen (30%) had prolonged noninvasive positive pressure ventilation use with median duration 110 hours (interquartile range, 52-130 hr). The median percentage change of diaphragm thickness at end-expiration from baseline among those with and without prolonged noninvasive positive pressure ventilation use was -20% (interquartile range, -32% to -10%) versus -7% (interquartile range, -21% to 0%) (p = 0.04).

CONCLUSIONS:

Diaphragm atrophy is associated with prolonged postextubation noninvasive positive pressure ventilation in children with acute respiratory failure. Serial bedside diaphragm ultrasound may identify children at risk for prolonged noninvasive positive pressure ventilation use after extubation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Insuficiencia Respiratoria / Ventilación no Invasiva Límite: Adolescent / Child / Humans Idioma: En Revista: Pediatr Crit Care Med Asunto de la revista: PEDIATRIA / TERAPIA INTENSIVA Año: 2020 Tipo del documento: Article País de afiliación: Panamá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Insuficiencia Respiratoria / Ventilación no Invasiva Límite: Adolescent / Child / Humans Idioma: En Revista: Pediatr Crit Care Med Asunto de la revista: PEDIATRIA / TERAPIA INTENSIVA Año: 2020 Tipo del documento: Article País de afiliación: Panamá