Two-body wear of occlusal splint materials against different antagonists.
BMC Oral Health
; 20(1): 174, 2020 06 22.
Article
en En
| MEDLINE
| ID: mdl-32571384
ABSTRACT
BACKGROUND:
This study aimed to demonstrate that the material of the occlusal splint can be chosen according to the needs of individual patients and contribute to the knowledge of the wear rate of these materials.METHODS:
In this study, four occlusal splint materials (Sr Ivocap Heat Cured, Valplast, SR Ivocap Elastomer and Eclipse) and three antagonists (natural tooth enamel, inCoris TZI and IPS e.max Press ceramic materials) were used. Each wear test was performed using a chewing simulator (n = 16; test load 50 N; number of cycles 10,000, 20,000 and 30,000; continuous rinsing with water at 30 °C for the wet condition). The Shapiro Wilk test was used for normal distribution suitability. Antagonist on average wear quantities both main effects and interactions of material, cycle and condition factors were investigated by Univariate variance analysis. Multiple comparisons were examined using the Games-Howell test.RESULTS:
There was a statistically significant effect of the difference in materials on the amount of wear (p < 0.001). Furthermore, there was a statistically significant difference among the mean values of all materials (p > 0.001). The highest mean value was obtained with Eclipse (0,318 µm3), and the lowest mean value was obtained with Valplast (0,134 µm3).CONCLUSION:
Our study found differences in the in vitro wear rate among various occlusal splint materials.Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Cerámica
/
Ferulas Oclusales
/
Esmalte Dental
Límite:
Humans
Idioma:
En
Revista:
BMC Oral Health
Asunto de la revista:
ODONTOLOGIA
Año:
2020
Tipo del documento:
Article
País de afiliación:
Turquía