Your browser doesn't support javascript.
loading
Determination of 30 Synthetic Cathinones in Postmortem Blood Using LC-MS-MS.
Lau, Timothy; Concheiro, Marta; Cooper, Gail.
Afiliación
  • Lau T; Department of Forensic Toxicology, New York City Office of Chief Medical Examiner, 520 First Ave., New York City, NY 10016, USA.
  • Concheiro M; Department of Sciences, John Jay College of Criminal Justice, City University of New York, 524 West 59th Street, Rm 5.66.02, New York City, NY 10019, USA.
  • Cooper G; Department of Forensic Toxicology, New York City Office of Chief Medical Examiner, 520 First Ave., New York City, NY 10016, USA.
J Anal Toxicol ; 44(7): 679-687, 2020 Oct 12.
Article en En | MEDLINE | ID: mdl-32591789
Synthetic cathinones, commonly referred to as "bath salts," are powerful amphetamine-like psychostimulants, and new derivatives are constantly appearing in the illicit market to evade judicial consequences. To keep up with these new stimulant drugs, a low-sample-size liquid chromatography-tandem mass spectrometry method was validated to quantify 30 synthetic cathinones in postmortem blood including N-ethylpentylone and eutylone. Mixed mode cation exchange solid-phase extraction using 0.25 mL postmortem blood was performed followed by detection using a triple quadrupole mass spectrometer operating electrospray ionization in positive mode. The reversed-phase chromatographic separation was achieved in 16 min, resolving all isobaric compounds. The linear range of the calibration curve was 1-500 ng/mL (R  2 > 0.99) for all compounds. Limit of quantification (LOQ) and limit of detection were determined to be at 1 ng/mL. Both imprecision and bias were evaluated and had met all allowed criteria (CV and bias <20%). No matrix effect was observed with values ranging from -5.1 to 13.3% (CV 11.4-17.5%, n = 10). Extraction efficiency (84.9-91.5%) and process efficiency (86.1-102.6%) were satisfactory, except for 4-chloroethcathinone which was 63 and 64.9%, respectively. No carryover after the upper LOQ was detected. Neither endogenous nor exogenous interferences were observed. Both dilution integrity and stability (24 h) yielded acceptable results. This method was applied to 18 postmortem cases received between 2015 and 2019. Eight different synthetic cathinones were detected in selected postmortem cases within the past 5 years, showing a wide range of concentrations from 1.4 to >500 ng/mL. While ethylone and methylone were detected in 2015, cases between 2016 and 2017 were predominantly butylone, dibutylone, pentylone and N-ethylpentylone which had also exhibited a significant increase in 2018. To our knowledge, this method is the most comprehensive methodology for the determination of up-to-date synthetic cathinones currently available in whole blood.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Detección de Abuso de Sustancias / Alcaloides / Toxicología Forense Límite: Humans Idioma: En Revista: J Anal Toxicol Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Detección de Abuso de Sustancias / Alcaloides / Toxicología Forense Límite: Humans Idioma: En Revista: J Anal Toxicol Año: 2020 Tipo del documento: Article País de afiliación: Estados Unidos