Your browser doesn't support javascript.
loading
Assessing paediatric exercise-induced bronchoconstriction using electromyography.
Keijzer, Pascal B; van der Kamp, Mattiènne R; Thio, Boony J; de Jongh, Frans H C; Driessen, Jean M M.
Afiliación
  • Keijzer PB; Medisch Spectrum Twente, Enschede, the Netherlands.
  • van der Kamp MR; University of Twente, Enschede, the Netherlands.
  • Thio BJ; Medisch Spectrum Twente, Enschede, the Netherlands.
  • de Jongh FHC; Roessingh Research and Development, Enschede, the Netherlands.
  • Driessen JMM; Medisch Spectrum Twente, Enschede, the Netherlands.
ERJ Open Res ; 6(2)2020 Apr.
Article en En | MEDLINE | ID: mdl-32613016
ABSTRACT

BACKGROUND:

Asthma is one of the most common chronic diseases in childhood, occurring in up to 10% of all children. Exercise-induced bronchoconstriction (EIB) is indicative of uncontrolled asthma and can be assessed using an exercise challenge test (ECT). However, this test requires children to undergo demanding repetitive forced breathing manoeuvres. We aimed to study the electrical activity of the diaphragm using surface electromyography (EMG) as an alternative measure to assess EIB.

METHODS:

Forty-two children suspected of EIB performed an ECT wearing a portable EMG amplifier. EIB was defined as a fall in FEV 1 of more than 13%. Children performed spirometry before exercise, and at 1, 3 and 6 min after exercise until the nadir FEV1 was attained and after the use of a bronchodilator. EMG measurements were obtained between spirometry measurements.

RESULTS:

Twenty out of 42 children were diagnosed with EIB. EMG peak amplitudes measured at the diaphragm increased significantly more in children with EIB; 4.85 µV (1.82-7.84), compared to children without EIB; 0.20 µV (-0.10-0.54), (p<0.001) at the lowest FEV 1 post-exercise. Furthermore, the increase in EMG peak amplitude could accurately distinguish between EIB and non-EIB using a cut-off of 1.15 µV (sensitivity 95%, specificity 91%).

CONCLUSION:

EMG measurements of the diaphragm are strongly related to the FEV1 and can accurately identify EIB. EMG measurements are a less invasive, effort-independent measure to assess EIB and could be an alternative when spirometry is not feasible.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: ERJ Open Res Año: 2020 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: ERJ Open Res Año: 2020 Tipo del documento: Article País de afiliación: Países Bajos