Your browser doesn't support javascript.
loading
Selective fluoride removal in capacitive deionization by reduced graphene oxide/hydroxyapatite composite electrode.
Park, Gyuleen; Hong, Sung Pil; Lee, Changha; Lee, Jaehan; Yoon, Jeyong.
Afiliación
  • Park G; School of Chemical and Biological Engineering, College of Engineering, Institute of Chemical Process (ICP), Seoul National University (SNU), 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Republic of Korea.
  • Hong SP; School of Chemical and Biological Engineering, College of Engineering, Institute of Chemical Process (ICP), Seoul National University (SNU), 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Republic of Korea.
  • Lee C; School of Chemical and Biological Engineering, College of Engineering, Institute of Chemical Process (ICP), Seoul National University (SNU), 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Republic of Korea.
  • Lee J; Department of Biological and Chemical Engineering, College of Science and Technology, Hongik University, 2639 Sejong-ro, Sejong-si 30016, Republic of Korea. Electronic address: ljh0322@hongik.ac.kr.
  • Yoon J; School of Chemical and Biological Engineering, College of Engineering, Institute of Chemical Process (ICP), Seoul National University (SNU), 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Republic of Korea; Korea Environment Institute, 370 Sicheong-daero, Sejong-si 30147, Republic of Korea. Electronic address
J Colloid Interface Sci ; 581(Pt A): 396-402, 2021 Jan 01.
Article en En | MEDLINE | ID: mdl-32771748
Capacitive deionization (CDI) is an emerging desalination technology with an environmental-friendly operation and energy-efficient properties. However, activated carbon (AC) used for CDI electrode does not have a significant preference toward anions, leading to unnecessary energy consumption for treating fluoridated water. Hence, we achieved selective fluoride removal in CDI system using a reduced graphene oxide/hydroxyapatite composite (rGO/HA), a novel fluoride selective electrode material. The results showed that the rGO/HA electrode has 4.9 times higher fluoride removal capacity than the AC electrode from a ternary solution consisting of fluoride, chloride, and nitrate ions. The fluoride removal capacity increased when the adequate voltage was applied. Furthermore, the rGO/HA electrode exhibited stability and reusability without significant capacity loss even after 50-cycle operation, maintaining about 0.21 mmol g-1 of fluoride removal capacity and approximately 96% of regeneration efficiency. Thus, this study suggests a novel electrode material for effective and selective fluoride removal in the CDI system.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Colloid Interface Sci Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Colloid Interface Sci Año: 2021 Tipo del documento: Article