Your browser doesn't support javascript.
loading
Integrated quantitative susceptibility and R2 * mapping for evaluation of liver fibrosis: An ex vivo feasibility study.
Jafari, Ramin; Hectors, Stefanie J; Koehne de González, Anne K; Spincemaille, Pascal; Prince, Martin R; Brittenham, Gary M; Wang, Yi.
Afiliación
  • Jafari R; Department of Radiology, Weill Medical College of Cornell University, New York, New York, 10021.
  • Hectors SJ; Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, 14853.
  • Koehne de González AK; Department of Radiology, Weill Medical College of Cornell University, New York, New York, 10021.
  • Spincemaille P; Department of Pathology, Columbia University Medical Center, New York, New York, 10032.
  • Prince MR; Department of Radiology, Weill Medical College of Cornell University, New York, New York, 10021.
  • Brittenham GM; Department of Radiology, Weill Medical College of Cornell University, New York, New York, 10021.
  • Wang Y; Department of Pediatrics, Columbia University, New York, New York, 10032.
NMR Biomed ; 34(1): e4412, 2021 01.
Article en En | MEDLINE | ID: mdl-32959425
To develop a method for noninvasive evaluation of liver fibrosis, we investigated the differential sensitivities of quantitative susceptibility mapping (QSM) and R2 * mapping using corrections for the effects of liver iron. Liver fibrosis is characterized by excessive accumulation of collagen and other extracellular matrix proteins. While collagen increases R2 * relaxation, measures of R2 * for fibrosis are confounded by liver iron, which may be present in the liver over a wide range of concentrations. The diamagnetic collagen contribution to susceptibility values measured by QSM is much less than the contribution of highly paramagnetic iron. In 19 ex vivo liver explants with and without fibrosis, QSM (χ), R2 * and proton density fat fraction (PDFF) maps were constructed from multiecho gradient-recalled echo (mGRE) sequence acquisition at 3 T. Median parameter values were recorded and differences between the MRI parameters in nonfibrotic vs. advanced fibrotic/cirrhotic samples were evaluated using Mann-Whitney U tests and receiver operating characteristic analyses. Logistic regression with stepwise feature selection was employed to evaluate the utility of combined MRI measurements for detection of fibrosis. Median R2 * increased in fibrotic vs. nonfibrotic liver samples (P = .041), while differences in χ and PDFF were nonsignificant (P = .545 and P = .395, respectively). Logistic regression identified the combination of χ and R2 * significant for fibrosis detection (logit [prediction] = -8.45 + 0.23 R2 * - 28.8 χ). For this classifier, a highly significant difference between nonfibrotic vs. advanced fibrotic/cirrhotic samples was observed (P = .002). The model exhibited an AUC of 0.909 (P = .003) for detection of advanced fibrosis/cirrhosis, which was substantially higher compared with AUCs of the individual parameters (AUC 0.591-0.784). An integrated QSM and R2 * analysis of mGRE 3 T imaging data is promising for noninvasive diagnostic assessment of liver fibrosis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Cirrosis Hepática Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Infant / Male / Middle aged Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Cirrosis Hepática Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Infant / Male / Middle aged Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2021 Tipo del documento: Article