Your browser doesn't support javascript.
loading
CPAP protects against hyperoxia-induced increase in airway reactivity in neonatal mice.
MacFarlane, Peter M; Mayer, Catherine A; Jafri, Anjum; Pabelick, Christina M; Prakash, Y S; Martin, Richard J.
Afiliación
  • MacFarlane PM; Department of Pediatrics, Division of Neonatology, Rainbow Babies & Children's Hospital, Case Western Reserve University, Cleveland, OH, USA.
  • Mayer CA; Department of Pediatrics, Division of Neonatology, Rainbow Babies & Children's Hospital, Case Western Reserve University, Cleveland, OH, USA.
  • Jafri A; Department of Pediatrics, Division of Neonatology, Rainbow Babies & Children's Hospital, Case Western Reserve University, Cleveland, OH, USA.
  • Pabelick CM; Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA.
  • Prakash YS; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
  • Martin RJ; Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA.
Pediatr Res ; 90(1): 52-57, 2021 07.
Article en En | MEDLINE | ID: mdl-33122799
ABSTRACT

BACKGROUND:

Oxygen and continuous positive airway pressure (CPAP) are primary modes of respiratory support for preterm infants. Animal models, however, have demonstrated adverse unintended effects of hyperoxia and CPAP on lung development. We investigate the effects of combined neonatal hyperoxia and CPAP exposure on airway function and morphology in mice.

METHODS:

Newborn mice were exposed to hyperoxia (40% O2) 24 h/day for 7 consecutive days with or without daily (3 h/day) concomitant CPAP. Two weeks after CPAP and/or hyperoxia treatment ended, lungs were assessed for airway (AW) hyperreactivity and morphology.

RESULTS:

CPAP and hyperoxia exposure alone increased airway reactivity compared to untreated control mice. CPAP-induced airway hyperreactivity was associated with epithelial and smooth muscle proliferation. In contrast, combined CPAP and hyperoxia treatment no longer resulted in increased airway reactivity, which was associated with normalization of smooth muscle and epithelial proliferation to values similar to untreated mice.

CONCLUSIONS:

Our data suggest that the combination of CPAP and hyperoxia decreases the adverse consequences on airway remodeling of either intervention alone. The complex interaction between mechanical stretch (via CPAP) and hyperoxia exposure on development of immature airways has implications for the pathophysiology of airway disease in former preterm infants receiving non-invasive respiratory support. IMPACT CPAP and mild hyperoxia exposure alone increase airway reactivity in the neonatal mouse model. In contrast, combined CPAP and hyperoxia no longer induce airway hyperreactivity. Combined CPAP and hyperoxia normalize smooth muscle and epithelial proliferation to control values. Interaction between CPAP-induced stretch and mild hyperoxia exposure on immature airways has important implications for airway pathophysiology in former preterm infants.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tráquea / Hiperoxia / Presión de las Vías Aéreas Positiva Contínua Tipo de estudio: Prognostic_studies Límite: Animals / Pregnancy Idioma: En Revista: Pediatr Res Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tráquea / Hiperoxia / Presión de las Vías Aéreas Positiva Contínua Tipo de estudio: Prognostic_studies Límite: Animals / Pregnancy Idioma: En Revista: Pediatr Res Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos