Your browser doesn't support javascript.
loading
Resonance Raman Spectroscopy Derived Tissue Hemoglobin Oxygen Saturation in Critically Ill and Injured Patients.
Tiba, Mohamad H; Awad, Abdelrahman B; Pennington, Amanda; Fung, Christopher M; Napolitano, Lena M; Park, Pauline K; Machado-Aranda, David A; Gunnerson, Kyle J; Romfh, Padraic; Ward, Kevin R.
Afiliación
  • Tiba MH; Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan.
  • Awad AB; Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan.
  • Pennington A; Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan.
  • Fung CM; Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan.
  • Napolitano LM; Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan.
  • Park PK; Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan.
  • Machado-Aranda DA; Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan.
  • Gunnerson KJ; Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan.
  • Romfh P; Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, Michigan.
  • Ward KR; Department of Surgery, University of Michigan, Ann Arbor, Michigan.
Shock ; 56(1): 92-97, 2021 07 01.
Article en En | MEDLINE | ID: mdl-33208679
BACKGROUND: In this study, we examined the ability of resonance Raman spectroscopy to measure tissue hemoglobin oxygenation (R-StO2) noninvasively in critically ill patients and compared its performance with conventional central venous hemoglobin oxygen saturation (ScvO2). METHODS: Critically ill patients (n = 138) with an indwelling central venous or pulmonary artery catheter in place were consented and recruited. R-StO2 measurements were obtained by placing a sensor inside the mouth on the buccal mucosa. R-StO2 was measured continuously for 5 min. Blood samples were drawn from the distal port of the indwelling central venous catheter or proximal port of the pulmonary artery catheter at the end of the test period to measure ScvO2 using standard co-oximetry analyzer. A regression algorithm was used to calculate the R-StO2 based on the observed spectra. RESULTS: Mean (SD) of pooled R-StO2 and ScvO2 were 64(7.6) % and 65(9.2) % respectively. A paired t test showed no significant difference between R-StO2 and ScvO2 with a mean(SD) difference of -1(7.5) % (95% CI: -2.2, 0.3%) with a Clarke Error Grid demonstrating 84.8% of the data residing within the accurate and acceptable grids. Area under the receiver operator curve for R-StO2's was 0.8(0.029) (95% CI: 0.7, 0.9 P < 0.0001) at different thresholds of ScvO2 (≤60%, ≤65%, and ≤70%). Clinical adjudication by five clinicians to assess the utility of R-StO2 and ScvO2 yielded Fleiss' Kappa agreement of 0.45 (P < 0.00001). CONCLUSIONS: R-StO2 has the potential to predict ScvO2 with high precision and might serve as a faster, safer, and noninvasive surrogate to these measures.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría Raman / Heridas y Lesiones / Hemoglobinas / Enfermedad Crítica / Saturación de Oxígeno Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Shock Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría Raman / Heridas y Lesiones / Hemoglobinas / Enfermedad Crítica / Saturación de Oxígeno Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Shock Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2021 Tipo del documento: Article