Cardiac Output Measurement With Echocardiography and Pressure Recording Analytical Method in Pediatric Patients Admitted to the Cardiac Intensive Care Unit: A Retrospective Assessment of Bias Between the Two Methods.
J Cardiothorac Vasc Anesth
; 35(5): 1351-1357, 2021 May.
Article
en En
| MEDLINE
| ID: mdl-33376069
OBJECTIVES: This study aimed to compare, in a cohort of critically ill children with biventricular anatomy and no cardiovascular shunt, cardiac output (CO) and cardiac index (CI) assessed by echocardiography and a continuous pulse-contour method, MostCareUP, to measure the differences between these techniques (biasCO and biasCI), and their association with clinical variables. DESIGN: Retrospective study. SETTING: Tertiary pediatric cardiac intensive care unit. PARTICIPANTS: Children admitted to the pediatric cardiac intensive care unit who underwent echocardiography with CO measurement. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Thirty-five patients were included. BiasCO was -0.02 (0.26) L/min (percentage error 36%). BiasCI was 0.07 (0.34) L/min/m2 (percentage error 18%). Biases and percentage errors were higher in 24 nonsupervised echocardiographies. A negative biasCO (overestimation by MostCareUP) was associated with post-surgical status (v cardiomyopathy), higher systolic arterial pressure, and spontaneous breathing (v intubation). When only absolute values were considered, biasCONONEG correlated with age, weight, arterial pressure, and heart rate, whereas biasCINONEG was associated with a femoral arterial cannula, no use of inotropes, and the absence of mechanical ventilation. After adjustment, biasCONONEG remained independently associated with patients' body weight(pâ¯=â¯0.0001). BiasCINONEG showed a nonlinear relationship with weight below 20 kg and above 40 kg. CONCLUSIONS: Children with extreme low or high weights, those who are extubated, and those with a femoral cannula carry the highest bias. When younger patients are considered, CI should be evaluated instead of CO, because biases are better highlighted by indexing data on body surface area. In children, both echocardiography and MostCareUP may be responsible of inaccurate CO/CI assessment.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Ecocardiografía
/
Unidades de Cuidados Intensivos
Tipo de estudio:
Observational_studies
/
Risk_factors_studies
Límite:
Child
/
Humans
Idioma:
En
Revista:
J Cardiothorac Vasc Anesth
Asunto de la revista:
ANESTESIOLOGIA
/
CARDIOLOGIA
Año:
2021
Tipo del documento:
Article