Your browser doesn't support javascript.
loading
Height and volume restoration in osteoporotic vertebral compression fractures: a biomechanical comparison of standard balloon kyphoplasty versus Tektona® in a cadaveric fracture model.
Krüger, Antonio; Bäumlein, Martin; Knauf, Tom; Pascal-Moussellard, Hugues; Ruchholtz, Steffen; Oberkircher, Ludwig.
Afiliación
  • Krüger A; Department of Trauma Surgery, Orthopaedic Surgery and Spine Surgery, Asklepios Hospital Lich GmbH, Lich, Germany.
  • Bäumlein M; Center for Orthopaedics and Trauma Surgery, Philipps University Marburg, Baldingerstraße, 35043, Marburg, Germany.
  • Knauf T; Center for Orthopaedics and Trauma Surgery, Philipps University Marburg, Baldingerstraße, 35043, Marburg, Germany.
  • Pascal-Moussellard H; Pitié- Salpêtrière Hospital, Université Pierre et Marie Curie - Paris VI, Orthopaedic dpt, Paris, France.
  • Ruchholtz S; Center for Orthopaedics and Trauma Surgery, Philipps University Marburg, Baldingerstraße, 35043, Marburg, Germany.
  • Oberkircher L; Center for Orthopaedics and Trauma Surgery, Philipps University Marburg, Baldingerstraße, 35043, Marburg, Germany. oberkirc@med.uni-marburg.de.
BMC Musculoskelet Disord ; 22(1): 76, 2021 Jan 13.
Article en En | MEDLINE | ID: mdl-33441095
BACKGROUND: Standard balloon kyphoplasty represents a well-established treatment option for osteoporotic vertebral compression fractures. Aim of the present study was to evaluate two different methods of percutaneous augmentation (standard balloon kyphoplasty (BKP) versus Tektona® (TEK)) with respect to height restoration. METHODS: Four-teen vertebral bodies of two female cadavers were examined. Fractures were created using a standardized protocol. CT-scans were taken before and after fracture, as well as after treatment. Afterwards two groups were randomly assigned in a matched pair design: 7 vertebral bodies (VB) were treated with BKP (Kyphon, Medtronic) and 7 vertebral bodies by TEK (Spineart, Switzerland) Anterior, central and posterior vertebral body heights were evaluated by CT-scans. Volumetry was performed using the CT-scans at three different timepoints. RESULTS: Values before fracture represent 100%. The anterior height after fracture was reduced to 75.99 (± 4.8) % for the BKP group and to 76.54 (± 9.17) % in the TEK Group. Statistically there was no difference for the groups (p = 1). After treatment the values increased to 93.06 (± 5) % for the BKP Group and 87.71 (± 6.2) % for the TEK Group. The difference before and after treatment was significant for both groups (BKP p = 0.0006; TEK p = 0.03). Within the groups, there was no difference (p = 0.13). The Volume of the vertebral body was reduced to 82.29 (± 8.4) % in the BKP Group and to 76.54 (± 8.6) % in the TEK Group. After treatment the volume was 89.26 (± 6.9) % for the BKP Group and 88.80 (± 8.7) % for the TEK Group. The difference before and after treatment was significant only for the TEK group (BKP p = 0.0728 n.s.; TEK p = 0.0175). Within the groups, there was no difference (p = 0.2). The average cement volume used was 6.1 (range 3.6-9 ml) for the BKP group and 5.3 (3-7.2 ml) for the TEK group respectively. CONCLUSIONS: Based on our results the new System Tektona® in osteoporotic compression fractures might represent a promising alternative for the clinical setting, especially preserving bone. Further biomechanical tests and clinical studies have to proof Tektona®`s capabilities.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas de la Columna Vertebral / Fracturas por Compresión / Fracturas Osteoporóticas / Cifoplastia Tipo de estudio: Guideline Límite: Adolescent / Female / Humans País/Región como asunto: Europa Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fracturas de la Columna Vertebral / Fracturas por Compresión / Fracturas Osteoporóticas / Cifoplastia Tipo de estudio: Guideline Límite: Adolescent / Female / Humans País/Región como asunto: Europa Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2021 Tipo del documento: Article País de afiliación: Alemania