Your browser doesn't support javascript.
loading
Analysis of Pembrolizumab in Human Plasma by LC-MS/HRMS. Method Validation and Comparison with Elisa.
Millet, Aurélien; Khoudour, Nihel; Guitton, Jérôme; Lebert, Dorothée; Goldwasser, François; Blanchet, Benoit; Machon, Christelle.
Afiliación
  • Millet A; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France.
  • Khoudour N; Department of Pharmacokinetics and Pharmacochemistry, Cochin Hospital, AP-HP, CARPEM 75014 Paris, France.
  • Guitton J; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France.
  • Lebert D; Toxicology Laboratory, Faculty of Pharmacy ISPBL, University of Lyon 1, F-69373 Lyon, France.
  • Goldwasser F; Promise Proteomics, 7 Parvis Louis Néel, F-38040 Grenoble, France.
  • Blanchet B; Department of Medical Oncology, Cochin Hospital, AP-HP, CARPEM, 75014 Paris, France.
  • Machon C; Department of Pharmacokinetics and Pharmacochemistry, Cochin Hospital, AP-HP, CARPEM 75014 Paris, France.
Biomedicines ; 9(6)2021 May 30.
Article en En | MEDLINE | ID: mdl-34070939
ABSTRACT
Pembrolizumab is a humanized immunoglobulin G4-kappa anti-PD1 antibody used in the treatment of different solid tumors or haematological malignancies. A liquid chromatography coupled with a high resolution mass spectrometry (orbitrap technology) method was fully developed, optimized, and validated for quantitative analysis of pembrolizumab in human plasma. A mass spectrometry assay was used for the first time a full-length stable isotope-labelled pembrolizumab-like (Arginine 13C6-15N4 and Lysine 13C6-15N2) as an internal standard; the sample preparation was based on albumin depletion and trypsin digestion and, finally, one surrogate peptide was quantified in positive mode. The assay showed good linearity over the range of 1-100 µg/mL, a limit of quantification at 1 µg/mL, excellent accuracy from 4.4% to 5.1%, and also a between-day precision below 20% at the limit of quantification. In parallel, an in-house ELISA was developed with a linearity range from 2.5 to 50 µg/mL. Then, results were obtained from 70 plasma samples of cancer patients that were treated with pembrolizumab and quantified with both methods were compared using the Passing-Bablok regression analysis and Bland-Altman plotting. The LC-MS/HRMS method is easy to implement in the laboratory for use in the context of PK/PD studies, clinical trials, or therapeutic drug monitoring.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Biomedicines Año: 2021 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Biomedicines Año: 2021 Tipo del documento: Article País de afiliación: Francia