Anti-biofouling implantable catheter using thin-film magnetic microactuators.
Yang, Qi; Park, Hyunsu; Nguyen, Tran N H; Rhoads, Jeffrey F; Lee, Albert; Bentley, R Timothy; Judy, Jack W; Lee, Hyowon.
Afiliación
  • Yang Q; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA.
  • Park H; Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA.
  • Nguyen TNH; Center for Implantable Devices, Purdue University, West Lafayette, IN 47907, USA.
  • Rhoads JF; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA.
  • Lee A; Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA.
  • Bentley RT; Center for Implantable Devices, Purdue University, West Lafayette, IN 47907, USA.
  • Judy JW; Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA.
  • Lee H; Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA.
Sens Actuators B Chem ; 273: 1694-1704, 2018 Nov 10.
Article en En | MEDLINE | ID: mdl-34276138
Here we report on the development of polyimide-based flexible magnetic actuators for actively combating biofouling that occurs in many chronically implanted devices. The thin-film flexible devices are microfabricated and integrated into a single-pore silicone catheter to demonstrate a proof-of-concept for a self-clearing smart catheter. The static and dynamic mechanical responses of the thin-film magnetic microdevices were quantitatively measured and compared to theoretical values. The mechanical fatigue properties of these polyimide-based microdevices were also characterized up to 300 million cycles. Finally, the biofouling removal capabilities of magnetically powered microdevices were demonstrated using bovine serum albumin and bioconjugated microbeads. Our results indicate that these thin-film microdevices are capable of significantly reducing the amount of biofouling. At the same time, we demonstrated that these microdevices are mechanically robust enough to withstand a large number of actuation cycles during its chronic implantation.