Your browser doesn't support javascript.
loading
Removable Partial Dentures with Polyetheretherketone Framework: The Influence on Residual Ridge Stability.
Lo Russo, Lucio; Chochlidakis, Konstantinos; Caradonna, Giammarco; Molinelli, Fabrizio; Guida, Laura; Ercoli, Carlo.
Afiliación
  • Lo Russo L; Department of Clinical and Experimental Medicine, School of Dentistry, University of Foggia, Foggia, Italy.
  • Chochlidakis K; Department of Periodontology, Eastman Institute for Oral Health, University of Rochester, Rochester, NY.
  • Caradonna G; Dental Officer, Dental Health Unit, MARINFERM, Italian Navy, La Spezia, Italy.
  • Molinelli F; Private practitioner, Ispra, VA, Italy.
  • Guida L; Private practitioner, Salus Oris srl, Vallesaccarda, AV, Italy.
  • Ercoli C; Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, NY.
J Prosthodont ; 31(4): 333-340, 2022 Apr.
Article en En | MEDLINE | ID: mdl-34288219
ABSTRACT

PURPOSE:

To provide, in a clinical case-control study, 1-year data on edentulous residual ridge dimensional changes for patients wearing removable partial dentures (RPD) with Polyetheretherketone (PEEK) framework, fabricated with a digital workflow, and a control group of untreated patients. MATERIALS AND

METHODS:

Ten patients were treated with PEEK RPD, and six controls were studied. Intraoral scans at baseline (T0) and after a median period of 1 year (T1) were superimposed, trimmed, and reoriented (T0r and T1r), moved to a metrology software, and realigned. A curve (C0) was then traced on T0r, along the residual ridge crest; its projection (C1) on T1r was obtained. The mean distance C0-C1 was the dependent variable of interest and represented the 1-year changes in the height of the edentulous ridge. In addition, mean 3D distance between T0 and T1 at each edentulous area was measured. Differences in these outcomes measured between RPD treated and control groups were statistically assessed.

RESULTS:

Twenty-six and 14 edentulous areas were investigated in the RPD treated and control groups, respectively. No significant differences were observed for potentially confounding variables, such as median follow-up time (12.5 vs. 13 months, respectively), the alignment accuracy between T0r and T1r (0.01 mm vs. 0 mm, respectively), the median number of remaining teeth (6 vs. 8.5, respectively), and the median length of edentulous areas (25.5 mm vs. 22.8 mm, respectively). For the outcomes of interest, no statistically significant difference was seen in the mean distance between C0 and C1 (i.e., changes in residual ridge height -0.39 ± 0.52 mm vs. -0.52 ± 0.54 mm, respectively) or in the mean 3D distance at corresponding points of the denture bearing areas (-0.3 ± 0.46 mm vs. -0.4 ± 0.35, respectively).

CONCLUSIONS:

Although 1 year is a relatively short observation period, this clinical study shows that there are no short-term differences in edentulous residual ridge height and overall dimensions between patients wearing PEEK RPD, fabricated with a digital workflow, and controls without an RPD.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Boca Edéntula / Dentadura Parcial Removible Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Prosthodont Asunto de la revista: ODONTOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Boca Edéntula / Dentadura Parcial Removible Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: J Prosthodont Asunto de la revista: ODONTOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Italia