Your browser doesn't support javascript.
loading
Diagnostic value of thyroid micronodules with high b-value diffusion weighted imaging: Comparative study with high-resolution ultrasound.
Zhang, Jun; Fu, Wan-Xi; Li, Wen-Ping; Zhang, Yun; Li, Jian-Jun; Zhou, Yang; Ren, He; Wang, Qing-Jun.
Afiliación
  • Zhang J; Department of Radiology, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Fu WX; Department of Ultrasound, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Li WP; Department of Radiology, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Zhang Y; Department of Radiology, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Li JJ; Department of General Surgery, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Zhou Y; Department of Pathology, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Ren H; Department of Ultrasound, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Wang QJ; Department of Radiology, The Sixth Medical Center, Chinese PLA General Hospital, Beijing, China. Electronic address: wangqingjun77@163.com.
Eur J Radiol ; 143: 109912, 2021 Oct.
Article en En | MEDLINE | ID: mdl-34450516
PURPOSE: This study aims to compare the diagnostic performance of two imaging methods for thyroid nodules ≤1.0 cm and reduce unnecessary overdiagnosis. METHODS: A retrospective study was conducted on 80 patients with pathologically confirmed solitary thyroid micronodules underwent both high-resolution ultrasound (HRUS) and High b-value (2000 s/mm2) diffusion weighted imaging (DWI). Intra- and interobserver agreement (Intraclass correlation coefficient) was followed by Kruskal-Wallis test to detect whether the quantitative apparent diffusion coefficient (ADC) and thyroid nodule subgroups were related. Cohen's kappa analysis was applied to assess the interobserver consistency of DWI and HRUS characteristics. The receiver operating characteristic curves were adopted for evaluating the diagnostic performance of thyroid malignancy. The sensitivity, specificity, and accuracy of the two imaging methods were compared using the McNemar's test and Kappa test. RESULTS: A total of 80 patients were included, consisting of 43 malignant and 37 benign micronodules. The sensitivity, specificity and accuracy of DWI combined with rADC (ADCmin to ADCn ratio) for the diagnosis of thyroid micronodules were 83.7%, 89.2% and 86.3%, respectively. The area under the curve (AUC) was 0.91 (95% confidence interval [CI]: 0.84-0.97). The sensitivity, specificity and accuracy of HRUS diagnosis were 100%, 62.16% and 82.5%, respectively. CONCLUSION: High b-value DWI is superior to HRUS for evaluating the diagnostic performance of solid thyroid micronodules. DWI and its ADC quantitative analysis could be added to the evaluation of thyroid micronodules to improve the specificity of diagnosis, reduce overdiagnosis and avoid unnecessary biopsies or surgeries.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Glándula Tiroides / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Eur J Radiol Año: 2021 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Glándula Tiroides / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Eur J Radiol Año: 2021 Tipo del documento: Article País de afiliación: China