BactoSpin: Novel Technology for Rapid Bacteria Detection and Antibiotic Susceptibility Testing.
Shumeiko, Vlad; Hidas, Guy; Nowogrodski, Chen; Pinto, Yariv; Gofrit, Ofer; Duvdevani, Mordechai; Shoseyov, Oded.
Afiliación
  • Shumeiko V; Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot 7610001, Israel.
  • Hidas G; Department of Urology, Hadassah Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112001, Israel.
  • Nowogrodski C; Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot 7610001, Israel.
  • Pinto Y; Center for Functional and 3D Printing, Center for Nanoscience and Nanotechnology, The Hebrew University of Jerusalem, Jerusalem 9190401, Israel.
  • Gofrit O; Department of Urology, Hadassah Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112001, Israel.
  • Duvdevani M; Department of Urology, Hadassah Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112001, Israel.
  • Shoseyov O; Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot 7610001, Israel.
Sensors (Basel) ; 21(17)2021 Sep 02.
Article en En | MEDLINE | ID: mdl-34502797
ABSTRACT
Inappropriate use of antibiotics is one of the leading causes of the increasing numbers of resistant bacteria strains, resulting in 700,000 deaths worldwide each year. Reducing unnecessary use of antibiotics and choosing the most effective antibiotics instead of broad-spectrum drugs will slow the arms race between germs and humans. Urinary tract infections (UTIs) are among the most common bacterial infections. Currently, accurate diagnosis of UTI requires approximately 48 h from the time of urine sample collection until antibiotic susceptibility test (AST) results. This work presents a rapid bacterial detection device that integrates a centrifuge, microscope, and incubator. Two disposable microfluidic chips were developed. The first chip was designed for bacteria concentration, detection, and medium exchange. A second multi-channel chip was developed for AST. This chip contains superhydrophobic and hydrophilic coatings to ensure liquid separation between the channels without the need for valves. The designed chips supported the detection of E. coli at a concentration as low as 5 × 103 cells/mL within 5 min and AST in under 2 h. AST was also successfully performed with Klebsiella pneumonia isolated from a human urine sample. In addition, machine-learning-based image recognition was shown to reduce the required time for AST and to provide results within 1 h for E. coli cells. Thus, the BactoSpin device can serve as an efficient and rapid platform for UTI diagnostics and AST.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Infecciones Urinarias / Escherichia coli Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Israel

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Infecciones Urinarias / Escherichia coli Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Israel