Your browser doesn't support javascript.
loading
Highly Sensitive Amperometric Detection of Hydrogen Peroxide in Saliva Based on N-Doped Graphene Nanoribbons and MnO2 Modified Carbon Paste Electrodes.
Gricar, Ema; Kalcher, Kurt; Genorio, Bostjan; Kolar, Mitja.
Afiliación
  • Gricar E; Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Vecna pot 113, 1000 Ljubljana, Slovenia.
  • Kalcher K; Department of Analytical Chemistry, Insistute of Chemistry, University of Graz, Universitätsplatz 1, 8020 Graz, Austria.
  • Genorio B; Department of Chemical Engineering and Technical Safety, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Vecna pot 113, 1000 Ljubljana, Slovenia.
  • Kolar M; Department of Chemistry and Biochemistry, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Vecna pot 113, 1000 Ljubljana, Slovenia.
Sensors (Basel) ; 21(24)2021 Dec 11.
Article en En | MEDLINE | ID: mdl-34960395
Four different graphene-based nanomaterials (htGO, N-htGO, htGONR, and N-htGONR) were synthesized, characterized, and used as a modifier of carbon paste electrode (CPE) in order to produce a reliable, precise, and highly sensitive non-enzymatic amperometric hydrogen peroxide sensor for complex matrices. CPE, with their robustness, reliability, and ease of modification, present a convenient starting point for the development of new sensors. Modification of CPE was optimized by systematically changing the type and concentration of materials in the modifier and studying the prepared electrode surface by cyclic voltammetry. N-htGONR in combination with manganese dioxide (1:1 ratio) proved to be the most appropriate material for detection of hydrogen peroxide in pharmaceutical and saliva matrices. The developed sensor exhibited a wide linear range (1.0-300 µM) and an excellent limit of detection (0.08 µM) and reproducibility, as well as high sensitivity and stability. The sensor was successfully applied to real sample analysis, where the recovery values for a commercially obtained pharmaceutical product were between 94.3% and 98.0%. Saliva samples of a user of the pharmaceutical product were also successfully analyzed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nanotubos de Carbono / Grafito Tipo de estudio: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Eslovenia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nanotubos de Carbono / Grafito Tipo de estudio: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Eslovenia