Your browser doesn't support javascript.
loading
Comparison of Six Phenotypic Assays with Reference Methods for Assessing Colistin Resistance in Clinical Isolates of Carbapenemase-Producing Enterobacterales: Challenges and Opportunities.
Foldes, Annamária; Székely, Edit; Voidazan, Septimiu Toader; Dobreanu, Minodora.
Afiliación
  • Foldes A; Department of Microbiology, Laboratory of Medical Analysis, "Dr. Constantin Opris" County Emergency Hospital, 430031 Baia Mare, Romania.
  • Székely E; Doctoral School of Medicine and Pharmacy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology, 540142 Targu Mures, Romania.
  • Voidazan ST; Department of Microbiology, Central Clinical Laboratory, County Emergency Clinical Hospital, 540136 Targu Mures, Romania.
  • Dobreanu M; Department of Microbiology, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology, 540142 Targu Mures, Romania.
Antibiotics (Basel) ; 11(3)2022 Mar 11.
Article en En | MEDLINE | ID: mdl-35326840
ABSTRACT
The global escalation of severe infections due to carbapenemase-producing Enterobacterales (CPE) isolates has prompted increased usage of parenteral colistin. Considering the reported difficulties in assessing their susceptibility to colistin, the purpose of the study was to perform a comparative evaluation of six phenotypic assays-the colistin broth disc elution (CBDE), Vitek 2 Compact (bioMérieux SA, Marcy l'Etoile, France), the Micronaut MIC-Strip Colistin (Merlin Diagnostika GMBH, Bornheim-Hensel, Germany), the gradient diffusion strip Etest (bioMérieux SA, Marcy l'Etoile, France), ChromID Colistin R Agar (COLR) (bioMérieux SA, Marcy l'Etoile, France), and the Rapid Polymyxin NP Test (ELITechGroup, Signes, France)-versus the reference method of broth microdilution (BMD). All false resistance results were further assessed using population analysis profiling (PAP). Ninety-two nonrepetitive clinical CPE strains collected from two hospitals were evaluated. The BMD confirmed 36 (39.13%) isolates susceptible to colistin. According to the BMD, the Micronaut MIC-Strip Colistin, the CBDE, and the COLR medium exhibited category agreement (CA) of 100%. In comparison with the BMD, the highest very major discrepancy (VMD) was noted for Etest (n = 15), and the only false resistance results were recorded for the Rapid Polymyxin NP Test (n = 3). Only the PAP method and the Rapid Polymyxin NP Test were able to detect heteroresistant isolates (n = 2). Thus, there is an urgent need to further optimize the diagnosis strategies for colistin resistance.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Antibiotics (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Rumanía

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Antibiotics (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Rumanía