Environmental Monitoring of Parvovirus B19 in the Kidney Transplantation Ward of a Chinese Teaching Hospital.
Wang, Fang; Zhan, Qing; Yu, Shi-Ping; Feng, Hai-Ting; Hu, Ping; Zhong, Zi-Feng; Qu, Ting-Ting.
Afiliación
  • Wang F; Infection Control Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
  • Zhan Q; Infection Control Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
  • Yu SP; Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
  • Feng HT; Infection Control Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
  • Hu P; Kidney Disease Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
  • Zhong ZF; Infection Control Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
  • Qu TT; Infection Control Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, People's Republic of China.
Infect Drug Resist ; 15: 1903-1910, 2022.
Article en En | MEDLINE | ID: mdl-35465250
ABSTRACT

Purpose:

Parvovirus B19 (B19V) infection is a viral threat after kidney transplantation. It is mainly transmitted by close-contact inhalation of aerosolized viral particles. The risk of nosocomial spread of B19V in the transplantation ward is quite high. This study aimed to evaluate the quality of routine disinfection and the effectiveness of isolation measures in the wards of B19V-infected kidney transplant recipients. Patients and

Methods:

Throat swab samples of 19 kidney transplant recipients admitted to the isolation ward and three healthcare workers (HCWs) were collected for viral DNA detection. Routine disinfection procedures were performed twice a day in general and B19V isolation wards. Environmental surface and air samples were collected for viral DNA detection before and after disinfection.

Results:

A total of four patients were diagnosed with B19V infection and transferred to the B19V isolation ward, of which only two had positive throat swab samples. The other 15 patients and all HCWs tested negative for B19V. A total of 88 environmental surface and air samples were collected. Eight of the environmental samples collected in the B19V isolation ward before disinfection tested positive for B19V, while one sample tested positive after disinfection. In the general wards, all environmental samples collected before disinfection tested negative for B19V. All 24 samples collected from ambient air, whether in B19V isolation or general wards, before or after disinfection, tested negative for B19V.

Conclusion:

Existing methods of routine or terminal disinfection for air and object surfaces were effective in eliminating B19V from object surfaces and ambient air in the isolation and general wards. Material surfaces that are exposed to high frequency and easily contaminated by blood, body fluids, and indoor air were the focus of cleaning and disinfection. Nosocomial cross-infection of other immunocompromised patients and HCWs can be avoided if appropriate prevention and control measures are taken.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Infect Drug Resist Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Infect Drug Resist Año: 2022 Tipo del documento: Article