Your browser doesn't support javascript.
loading
Development and Validation of a Quantitative Method for Multiple Allergen Detection in Food Using Concatemer-Based Isotope Dilution Mass Spectrometry.
Gavage, Maxime; Van Vlierberghe, Kaatje; Dieu, Marc; Renard, Patsy; Arnould, Thierry; De Loose, Marc; Gevaert, Kris; Gillard, Nathalie; Van Poucke, Christof.
Afiliación
  • Gavage M; CER Groupe, Rue du Point du Jour 8, 6900 Marloie, Belgium.
  • Van Vlierberghe K; ILVO Flanders Research Institute for Agriculture, Fisheries and Food, Technology and Food Science Unit, Brusselsesteenweg 370, 9090 Melle, Belgium.
  • Dieu M; University of Namur, Laboratory of Biochemistry and Cell Biology (URBC), Namur Research Institute for Life Sciences (NARILIS), Rue de Bruxelles 61, 5000 Namur, Belgium.
  • Renard P; University of Namur, Laboratory of Biochemistry and Cell Biology (URBC), Namur Research Institute for Life Sciences (NARILIS), Rue de Bruxelles 61, 5000 Namur, Belgium.
  • Arnould T; University of Namur, Laboratory of Biochemistry and Cell Biology (URBC), Namur Research Institute for Life Sciences (NARILIS), Rue de Bruxelles 61, 5000 Namur, Belgium.
  • De Loose M; ILVO Flanders Research Institute for Agriculture, Fisheries and Food, Technology and Food Science Unit, Brusselsesteenweg 370, 9090 Melle, Belgium.
  • Gevaert K; VIB-UGent Center for Medical Biotechnology, Technologiepark-Zwijnaarde 75, 9052 Ghent, Belgium.
  • Gillard N; Ghent University, Department of Biomolecular Medicine, Technologiepark-Zwijnaarde 75, 9052 Ghent, Belgium.
  • Van Poucke C; CER Groupe, Rue du Point du Jour 8, 6900 Marloie, Belgium.
J AOAC Int ; 105(6): 1585-1595, 2022 Oct 26.
Article en En | MEDLINE | ID: mdl-35532071
ABSTRACT

BACKGROUND:

Accurate food labeling is essential to protect allergic consumers. However, allergen contaminations may occur during the whole food production process. Reliable, sensitive, and robust methods for detecting multiple allergens in food are needed.

OBJECTIVE:

This work aims to develop and validate an LC coupled to tandem mass spectrometry (MS/MS) method for the detection and quantification of hazelnuts, peanuts, milk, and eggs in processed food products.

METHODS:

In-house-produced incurred test materials, cookies and chocolates, were used for the method development and validation. The quantification was based on the standard addition strategy using qualified reference materials as allergen protein standards and an innovative stable isotope-labeled concatemer as an internal standard.

RESULTS:

A method targeting 19 allergen-specific peptides was developed and validated in two laboratories, which strengthens its robustness. The AOAC INTERNATIONAL performance requirements for repeatability, intermediate precision, reproducibility, and recovery were reached for at least one peptide per allergen across both matrixes, and quantification limits complied with the action levels of the Food Industry Guide to the Voluntary Incidental Trace Allergen Labelling (VITAL®) Program Version 3.0.

CONCLUSION:

The combination of incurred test materials, standard addition strategy, and stable isotope-labeled concatemer as an internal standard allowed us to develop and validate a robust method for detecting and quantifying multiple allergens in food with sufficient sensitivity to protect allergic consumers. HIGHLIGHTS The combination of characterized incurred test material, calibration with certified reference material, a single stable isotope labelled concatemer and cross-lab validation result in the required standardization and harmonization in food allergen detection according to the stakeholders' group to assess the robustness of our method.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Alérgenos / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Idioma: En Revista: J AOAC Int Año: 2022 Tipo del documento: Article País de afiliación: Bélgica