Your browser doesn't support javascript.
loading
Open-porous magnesium-based scaffolds withstand in vitro corrosion under cyclic loading: A mechanistic study.
Bonithon, Roxane; Lupton, Colin; Roldo, Marta; Dunlop, Joseph Nicholas; Blunn, Gordon William; Witte, Frank; Tozzi, Gianluca.
Afiliación
  • Bonithon R; Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Road, PO1 3DJ, Portsmouth, United Kingdom.
  • Lupton C; Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Road, PO1 3DJ, Portsmouth, United Kingdom.
  • Roldo M; School of Pharmacy and Biomedical Sciences, University of Portsmouth, White Swan Road, PO1 2DT, Portsmouth, United Kingdom.
  • Dunlop JN; School of the Environment, Geography & Geosciences, University of Portsmouth, Burnaby Road, PO1 3QL, Portsmouth, United Kingdom.
  • Blunn GW; School of Pharmacy and Biomedical Sciences, University of Portsmouth, White Swan Road, PO1 2DT, Portsmouth, United Kingdom.
  • Witte F; Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Aßmannshauser Straße 4-6, 14197, Berlin, Germany.
  • Tozzi G; Biotrics Bioimplants AG, Ullsteinstr. 108, 12109, Berlin, Germany.
Bioact Mater ; 19: 406-417, 2023 Jan.
Article en En | MEDLINE | ID: mdl-35574056
ABSTRACT
The successful application of magnesium (Mg) alloys as biodegradable bone substitutes for critical-sized defects may be comprised by their high degradation rate resulting in a loss of mechanical integrity. This study investigates the degradation pattern of an open-porous fluoride-coated Mg-based scaffold immersed in circulating Hanks' Balanced Salt Solution (HBSS) with and without in situ cyclic compression (30 N/1 Hz). The changes in morphological and mechanical properties have been studied by combining in situ high-resolution X-ray computed tomography mechanics and digital volume correlation. Although in situ cyclic compression induced acceleration of the corrosion rate, probably due to local disruption of the coating layer where fatigue microcracks were formed, no critical failures in the overall scaffold were observed, indicating that the mechanical integrity of the Mg scaffolds was preserved. Structural changes, due to the accumulation of corrosion debris between the scaffold fibres, resulted in a significant increase (p < 0.05) in the material volume fraction from 0.52 ± 0.07 to 0.47 ± 0.03 after 14 days of corrosion. However, despite an increase in fibre material loss, the accumulated corrosion products appear to have led to an increase in Young's modulus after 14 days as well as lower third principal strain (εp3) accumulation (-91000 ± 6361 µÎµ and -60093 ± 2414 µÎµ after 2 and 14 days, respectively). Therefore, this innovative Mg scaffold design and composition provide a bone replacement, capable of sustaining mechanical loads in situ during the postoperative phase allowing new bone formation to be initially supported as the scaffold resorbs.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Bioact Mater Año: 2023 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Bioact Mater Año: 2023 Tipo del documento: Article País de afiliación: Reino Unido