Accelerated 3D myelin water imaging using joint spatio-temporal reconstruction.
Lee, Jae-Hun; Yi, Jaeuk; Kim, Jun-Hyeong; Ryu, Kanghyun; Han, Dongyeob; Kim, Sewook; Lee, Seul; Kim, Deog Young; Kim, Dong-Hyun.
Afiliación
  • Lee JH; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Yi J; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Kim JH; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Ryu K; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Han D; Department of Radiology, Stanford University, Stanford, California, USA.
  • Kim S; Siemens Healthineers Ltd, Seoul, Republic of Korea.
  • Lee S; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Kim DY; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Kim DH; Department of Research Institute of Rehabilitation Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea.
Med Phys ; 49(9): 5929-5942, 2022 Sep.
Article en En | MEDLINE | ID: mdl-35678751
ABSTRACT

PURPOSE:

To enable acceleration in 3D multi-echo gradient echo (mGRE) acquisition for myelin water imaging (MWI) by combining joint parallel imaging (JPI) and joint deep learning (JDL).

METHODS:

We implemented a multistep reconstruction process using both advanced parallel imaging and deep learning network which can utilize joint spatiotemporal components between the multi-echo images to further accelerate 3D mGRE acquisition for MWI. In the first step, JPI was performed to estimate missing k-space lines. Next, JDL was implemented to reduce residual artifacts and produce high-fidelity reconstruction by using variable splitting optimization consisting of spatiotemporal denoiser block, data consistency block, and weighted average block. The proposed method was evaluated for MWI with 2D Cartesian uniform under-sampling for each echo, enabling scan times of up to approximately 2 min for 2 mm × 2 mm × 2 mm $2\ {\rm mm} \times 2\ {\rm mm} \times 2\ {\rm mm}$ 3D coverage.

RESULTS:

The proposed method showed acceptable MWI quality with improved quantitative values compared to both JPI and JDL methods individually. The improved performance of the proposed method was demonstrated by the low normalized mean-square error and high-frequency error norm values of the reconstruction with high similarity to the fully sampled MWI.

CONCLUSION:

Joint spatiotemporal reconstruction approach by combining JPI and JDL can achieve high acceleration factors for 3D mGRE-based MWI.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Vaina de Mielina Idioma: En Revista: Med Phys Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Vaina de Mielina Idioma: En Revista: Med Phys Año: 2022 Tipo del documento: Article