Your browser doesn't support javascript.
loading
Fatty acid ethyl esters (FAEE) in virgin olive oil: A shorter and full validated approach as an alternative to the EU Official Method.
Gómez-Coca, Raquel B; Pérez-Camino, María Del Carmen; Brereton, Paul; Bendini, Alessandra; Gallina Toschi, Tullia; Moreda, Wenceslao.
Afiliación
  • Gómez-Coca RB; Department of Characterization and Quality of Lipids, Instituto de la Grasa -CSIC-, Ctra. Utrera km 1, E-41013 Sevilla, Spain. Electronic address: raquel.coca@ig.csic.es.
  • Pérez-Camino MDC; Department of Characterization and Quality of Lipids, Instituto de la Grasa -CSIC-, Ctra. Utrera km 1, E-41013 Sevilla, Spain.
  • Brereton P; Institute for Global Food Security, Queen's University Belfast, BT9 5BN, Northern Ireland.
  • Bendini A; Department of Agricultural and Food Sciences, Alma Mater Studiorum - Università di Bologna, Piazza Goidanich 60, 47521 Cesena, Italy.
  • Gallina Toschi T; Department of Agricultural and Food Sciences, Alma Mater Studiorum - Università di Bologna, Piazza Goidanich 60, 47521 Cesena, Italy.
  • Moreda W; Department of Characterization and Quality of Lipids, Instituto de la Grasa -CSIC-, Ctra. Utrera km 1, E-41013 Sevilla, Spain.
Food Chem ; 394: 133300, 2022 Nov 15.
Article en En | MEDLINE | ID: mdl-35777252
In this work a SPE/GC-FID method, incorporating the use of a 1-g silica cartridge, for the determination of FAEE in olive oils is presented. The procedure has been fully validated, initially 'in-house' and subsequently by an international validation study involving sixteen laboratories from Europe, the United States of America, and China. Key performance parameters of the method are: (1) Linearity in the 10-134 mg/kg range (R2 > 0.999), (2) LOD and LOQ < 0.5 mg/kg, (3) RSDr < 10%, (4) RSDR < 20% (for 4 out of 5 test materials). In addition, the method has been demonstrated to provide equivalent results to the Official Method (Commission Regulation 2568/91) while providing advantages in terms of reductions in time and solvents and ease of automation. In fact, the proposed protocol requires 30 mL solvents and takes 1.5 h per determination instead of the 350 mL and 6 h needed in the UE Official Method.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ésteres / Ácidos Grasos País/Región como asunto: Asia Idioma: En Revista: Food Chem Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ésteres / Ácidos Grasos País/Región como asunto: Asia Idioma: En Revista: Food Chem Año: 2022 Tipo del documento: Article