Your browser doesn't support javascript.
loading
A high-performance liquid chromatography method for simultaneous quantification of metformin and ferulic acid in solid dosage forms.
Chaves Júnior, José Venâncio; Muniz, Vanessa Morais; de Almeida, Vinícius Cleithon Rodrigues; de Souza, Fábio Santos; Aragão, Cícero Flávio Soares.
Afiliación
  • Chaves Júnior JV; Pharmacy Department, Federal University of Rio Grande do Norte, Natal, 59010-115, Brasil.
  • Muniz VM; Pharmaceutical Sciences Department, Paraíba Federal University, João Pessoa, 58051-970, Brasil.
  • de Almeida VCR; Pharmacy Department, Federal University of Rio Grande do Norte, Natal, 59010-115, Brasil.
  • de Souza FS; Pharmaceutical Sciences Department, Paraíba Federal University, João Pessoa, 58051-970, Brasil.
  • Aragão CFS; Pharmacy Department, Federal University of Rio Grande do Norte, Natal, 59010-115, Brasil.
J Sep Sci ; 45(20): 3866-3873, 2022 Oct.
Article en En | MEDLINE | ID: mdl-36057131
ABSTRACT
Metformin is one of the most commonly used drugs in the world for the treatment of type 2 diabetes, while ferulic acid is a molecule that stands out for its antioxidant potential. Recent studies demonstrate hypoglycemic synergy between these molecules. The objective of this study is to develop and validate an analytical methodology by high-performance liquid chromatography for the simultaneous quantification of these drugs in pharmaceutical formulations. The method used an octadecylsilane column and a mobile phase composed of 6 mM sodium lauryl sulfate in 15 mM phosphate bufferACN (6535). Ferulic acid and metformin were monitored at 232 nm, with a mobile phase flow rate of 1 ml/min and oven temperature at 40°C. The method was linear in the range of 5-25 µg/ml for both molecules. In the presence of degradation products, satisfactory selectivity was achieved. Accuracy values were close to 100% and standard deviations in precision were less than 2%. In the robustness evaluation, the proposed variations did not interfere with the quantification. Therefore, it is concluded that the present method can be safely applied to the quality control of ferulic acid and metformin raw materials, as well as when they are combined in pharmaceutical formulations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diabetes Mellitus Tipo 2 / Metformina Límite: Humans Idioma: En Revista: J Sep Sci Año: 2022 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diabetes Mellitus Tipo 2 / Metformina Límite: Humans Idioma: En Revista: J Sep Sci Año: 2022 Tipo del documento: Article País de afiliación: Brasil