Your browser doesn't support javascript.
loading
Anastomotic Rings and Inflammation Values as Biomarkers for Leakage of Stapled Circular Colorectal Anastomoses.
Zhang, Feng; Qiao, Song; Yao, Ning; Li, Chunqiao; Weber, Marie-Christin; Jefferies, Benedict; Friess, Helmut; Reischl, Stefan; Neumann, Philipp-Alexander.
Afiliación
  • Zhang F; Department of Surgery, Klinikum rechts der Isar, School of Medicine, Technical University of Munich (TUM), 81675 Munich, Germany.
  • Qiao S; Department of General Surgery, Tongren Municipal People's Hospital of Guizhou Medical University (GMU), Tongren 554300, China.
  • Yao N; Department of General Surgery, Tongren Municipal People's Hospital of Guizhou Medical University (GMU), Tongren 554300, China.
  • Li C; Department of Pathology, Tongren Municipal People's Hospital of Guizhou Medical University (GMU), Tongren 554300, China.
  • Weber MC; Department of Surgery, Klinikum rechts der Isar, School of Medicine, Technical University of Munich (TUM), 81675 Munich, Germany.
  • Jefferies B; Department of Surgery, Klinikum rechts der Isar, School of Medicine, Technical University of Munich (TUM), 81675 Munich, Germany.
  • Friess H; Department of Surgery, Klinikum rechts der Isar, School of Medicine, Technical University of Munich (TUM), 81675 Munich, Germany.
  • Reischl S; Department of Surgery, Klinikum rechts der Isar, School of Medicine, Technical University of Munich (TUM), 81675 Munich, Germany.
  • Neumann PA; Institute of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich (TUM), 81675 Munich, Germany.
Diagnostics (Basel) ; 12(12)2022 Nov 22.
Article en En | MEDLINE | ID: mdl-36552909
ABSTRACT
Reliable markers to predict or diagnose anastomotic leakage (AL) of stapled circular anastomoses following colorectal resections are an important clinical need. Here, we aim to quantitatively investigate the morphology of anastomotic rings as an early available prognostic marker for AL and compare them to established inflammatory markers. We perform a prospective single-center cohort study, including patients undergoing stapled circular anastomosis between August 2020 and August 2021. The predictive value of the anastomotic ring configuration and the neutrophil-to-lymphocyte ratio (NLR) regarding anastomotic leakage is examined by ROC analyses and compared to the C-reactive protein (CRP) as an established marker. We included 204 patients, of which 19 suffered from anastomotic leakage (LEAK group), while in 185 patients the anastomoses healed well (HEAL group). The minimal height of the anastomotic rings as a binary classifier had a good ROC-AUC of 0.81 but was inferior to the NLR at postoperative day (POD) 5, with an excellent ROC-AUC of 0.93. Still, it was superior to the NLR at POD 3 (0.74) and the CRP at POD 3 (ROC-AUC 0.54) and 5 (ROC-AUC 0.70). The minimal height of the anastomotic rings as indicator for technically insufficient anastomoses is a good predictor of AL, while postoperatively the NLR was superior to the CRP in prediction of AL.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Observational_studies / Risk_factors_studies Idioma: En Revista: Diagnostics (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Observational_studies / Risk_factors_studies Idioma: En Revista: Diagnostics (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Alemania