Multiple-site decontamination in mechanically ventilated ICU patients: A real-life study.
Massart, Nicolas; Dupin, Clarisse; Legris, Eleonore; Fedun, Yannick; Barbarot, Nicolas; Legay, François; Wattecamps, Guilhem; Le Gall, Florence; La Combe, Béatrice; Bouju, Pierre; Frerou, Aurélien; Muller, Laura; Rieul, Guillaume; Fillatre, Pierre.
Afiliación
  • Massart N; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France. Electronic address: nicolasmassart@hotmail.fr.
  • Dupin C; Service de Microbiologie, CH de St BRIEUC, 10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Legris E; Service de Pharmacie, CH de St BRIEUC, 10, rue marcel Proust 22000 Saint-Brieuc, France.
  • Fedun Y; Service de Réanimation, CH de Vannes, 20, bd Maurice Guillaudot,56000 Vannes, France.
  • Barbarot N; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France.
  • Legay F; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France.
  • Wattecamps G; Service de Réanimation, CH de QUIMPER, 14bis Avenue Yves Thépot, 29107 Quimper, France.
  • Le Gall F; Service de Microbiologie, CH de QUIMPER, 14bis Avenue Yves Thépot, 29107 Quimper, France.
  • La Combe B; Service de Réanimation, CH bretagne SUD, LORIENT, 5 avenue de choiseul, 56322 Lorient, France.
  • Bouju P; Service de Réanimation, CH bretagne SUD, LORIENT, 5 avenue de choiseul, 56322 Lorient, France.
  • Frerou A; Service de Réanimation, CH de Saint-Malo, 1 rue de la marne 35400 Saint-Malo, France.
  • Muller L; Service de Réanimation, CH de Saint-Malo, 1 rue de la marne 35400 Saint-Malo, France.
  • Rieul G; Service de Réanimation, CH de Vannes, 20, bd Maurice Guillaudot,56000 Vannes, France.
  • Fillatre P; Service de Réanimation, CH de St BRIEUC, 10, rue Marcel Proust 22000 Saint-Brieuc, France.
Infect Dis Now ; 53(3): 104666, 2023 Apr.
Article en En | MEDLINE | ID: mdl-36736667
INTRODUCTION: Decontamination regimen decreases acquired infection (ICU-AI) incidence but has remained controversial, mostly because it contains a course of intravenous antibiotic. Multiple-site decontamination (MSD), which does not include systemic antibiotics, has been less widely studied but is associated with lower risks of ventilator-associated pneumonia (VAP), bloodstream infection (BSI) and multidrug resistant micro-organism (MDRO) acquisition. We aimed to confirm these favorable outcomes. METHODS: A prospective pre/post-observational study was conducted in 5 ICUs in western France. Among them, 4 implemented MSD, whereas the fifth applied standard care (SC) throughout the study period. Patients who required intubation were eligible for study and divided into two groups: the MSD group if they were admitted to an ICU that already implemented MSD, or the SC group. The primary objective was to measure ICU-AI incidence. RESULTS: Close to 1400 (1346) patients were available for analysis (334 in the MSD and 1012 patients in the SC group). In a multivariable Poisson regression model, MSD was independently associated with decreased incidence of ICU-AI (IRR = 0.33; 95 %CI [0.18-0.60] p < 0.001). Non-parsimonious propensity-score matching resulted in 334 patient-pairs with well-balanced baseline characteristics. There was a lower incidence of ICU-AI(6.3 % vs 20.7 % p < 0.001), VAP (3.6 % vs 16.2 % p < 0.001) and BSI (3.0 % vs 7.2 % p = 0.029) in the MSD group as compared with the SC group. Five (1.5 %) and 11 (3.3 %) patients respectively acquired MDRO (p = 0.206). CONCLUSION: MSD is associated with decreased risk of ICU-AI, VAP and BSI, with no increase in MDRO acquisition.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Respiración Artificial / Neumonía Asociada al Ventilador Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Infect Dis Now Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Respiración Artificial / Neumonía Asociada al Ventilador Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Infect Dis Now Año: 2023 Tipo del documento: Article