Your browser doesn't support javascript.
loading
Contrast analysis in ultrafast ultrasound blood flow imaging of jugular vein.
Omura, Masaaki; Yagi, Kunimasa; Nagaoka, Ryo; Hasegawa, Hideyuki.
Afiliación
  • Omura M; Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama, 93008555, Japan. momura@eng.u-toyama.ac.jp.
  • Yagi K; School of Medicine, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Kahoku, Ishikawa, 9200293, Japan.
  • Nagaoka R; Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama, 93008555, Japan.
  • Hasegawa H; Faculty of Engineering, University of Toyama, 3190 Gofuku, Toyama, 93008555, Japan. hasegawa@eng.u-toyama.ac.jp.
J Med Ultrason (2001) ; 50(2): 131-141, 2023 Apr.
Article en En | MEDLINE | ID: mdl-36757634
PURPOSE: The contrasts of flowing blood in in vitro experiments using porcine blood and in vivo measurements of human jugular veins were analyzed to demonstrate that the hemorheological property was dependent on the shear rate. METHODS: Blood samples (45% hematocrit) suspended in saline or plasma were compared with examine the difference in viscoelasticity. Ultrafast plane-wave imaging at an ultrasonic center frequency of 7.5 MHz was performed on different steady flows in a graphite-agar phantom. Also, in vivo measurement was performed in young, healthy subjects and patients with diabetes. A spatiotemporal matrix of beamformed radio-frequency data was used for the singular value decomposition (SVD) clutter filter. The clutter-filtered B-mode image was calculated as the amplitude envelope normalized at the first frame in the diastolic phase to evaluate contrast. The shear rate was estimated as the velocity gradient perpendicular to the lateral axis. RESULTS: Although nonaggregated erythrocytes at a high shear rate exhibited a low echogenicity, the echogenicity in the plasma sample overall increased due to erythrocyte aggregation at a low shear rate. In addition, the frequency of detection of specular components, defined as components beyond twice the standard deviation of a contrast map obtained from a clutter-filtered B-mode image, increased in the porcine blood at a high shear rate and the venous blood in healthy subjects versus patients with diabetes. CONCLUSION: The possibility of characterizing hemorheological properties dependent on the shear rate and diabetes condition was indicated using ultrafast plane-wave imaging with an SVD-based clutter filter.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agregación Eritrocitaria / Venas Yugulares Tipo de estudio: Diagnostic_studies Límite: Animals / Humans Idioma: En Revista: J Med Ultrason (2001) Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agregación Eritrocitaria / Venas Yugulares Tipo de estudio: Diagnostic_studies Límite: Animals / Humans Idioma: En Revista: J Med Ultrason (2001) Año: 2023 Tipo del documento: Article País de afiliación: Japón