Your browser doesn't support javascript.
loading
An antibody-free LC-MS/MS method for the quantification of sex hormone binding globulin in human serum and plasma.
Sleumer, Bas; Zwerwer, Jordan; van Faassen, Martijn; Vos, Michel J; Bischoff, Rainer; Kema, Ido P; van de Merbel, Nico C.
Afiliación
  • Sleumer B; ICON Bioanalytical Laboratories, Assen, The Netherlands.
  • Zwerwer J; Department of Analytical Biochemistry, University of Groningen, Groningen, The Netherlands.
  • van Faassen M; Department of Laboratory Medicine, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • Vos MJ; ICON Bioanalytical Laboratories, Assen, The Netherlands.
  • Bischoff R; Department of Analytical Biochemistry, University of Groningen, Groningen, The Netherlands.
  • Kema IP; Department of Laboratory Medicine, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
  • van de Merbel NC; Department of Laboratory Medicine, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Clin Chem Lab Med ; 61(7): 1266-1274, 2023 06 27.
Article en En | MEDLINE | ID: mdl-36773321
OBJECTIVES: Sex hormone binding globulin (SHBG) is a hormone binding protein which plays an important role in regulating the transport and availability of biologically active androgens and estradiol to target cells and used to calculate free testosterone concentrations. METHODS: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, featuring an albumin removal step followed by a tryptic digestion. After a reduction step with dithiothreitol and alkylation with iodoacetamide three signature peptides were used for the quantification of SHBG. RESULTS: The method enables the quantification of serum and plasma SHBG over the clinically relevant range of 200-20,000 ng/mL and was validated according to the most recent guidelines. The LC-MS/MS method correlates well with the Abbott Alinity immunoassay (R2>0.95), but the LC-MS/MS results are on average 16-17% lower than the immunoassay results, which is consistent for all three signature peptides. CONCLUSIONS: The LC-MS/MS method which includes an albumin depletion step allows quantification of SHBG in serum and plasma without an immunocapture step at clinically relevant SHBG levels, thus contributing to better lab-to-lab consistency of results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Globulina de Unión a Hormona Sexual / Espectrometría de Masas en Tándem Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Globulina de Unión a Hormona Sexual / Espectrometría de Masas en Tándem Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos