Your browser doesn't support javascript.
loading
A Case Report of Acute Cardiac Tamponade Creation in a Macaque: Echo-Guided Catheter Manipulation to Perforate Coronary Artery.
Takanari, Hiroki; Okuyama, Minami W; Kuroki, Kohji; Kondo, Hidekazu; Kira, Shintaro; Miura, Masahiro; Takahashi, Naohiko; Okuda, Takahisa.
Afiliación
  • Takanari H; Department of Pathophysiology, Faculty of Medicine, Oita University, Yufu 879-5593, Japan.
  • Okuyama MW; Division of Interdisciplinary Research for Medicine and Photonics, Institute of Post-LED Photonics, Tokushima University, Tokushima 770-8506, Japan.
  • Kuroki K; Department of Medicine, Faculty of Medicine, Oita University, Yufu 879-5593, Japan.
  • Kondo H; Division of Laboratory Animal Science, Institute for Research Management, Oita University, Oita 870-1192, Japan.
  • Kira S; Department of Forensic Medicine, Faculty of Medicine, Oita University, Yufu 879-5593, Japan.
  • Miura M; Imaging Center for Basic Medicine, Faculty of Medicine, Oita University, Yufu 879-5593, Japan.
  • Takahashi N; Department of Cardiology and Clinical Examination, Faculty of Medicine, Oita University, Yufu 879-5593, Japan.
  • Okuda T; Department of Anatomy, Faculty of Medicine, Oita University, Yufu 879-5593, Japan.
Yonago Acta Med ; 66(1): 192-195, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36811027
Although acute cardiac tamponade is one of the major problems in clinical practice, a suitable animal model is still lacking. We tried to create acute cardiac tamponade in macaques by echo-guided catheter manipulation. A 13-year-old male macaque was anesthetized, and a long sheath was inserted into the left ventricle via the left carotid artery under the guidance of transthoracic echocardiography. The sheath was then inserted into the orifice of the left coronary artery to perforate the proximal site of the left anterior descending branch. A cardiac tamponade was successfully created. Injection of diluted contrast agent into the pericardial space via a catheter made it possible to clearly distinguish between the hemopericardium and the surrounding tissues on postmortem computed tomography. This procedure did not need an X-ray imaging system during catheterization. Our present model would help us examine the intrathoracic organs in the presence of acute cardiac tamponade.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: Yonago Acta Med Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: Yonago Acta Med Año: 2023 Tipo del documento: Article País de afiliación: Japón