Your browser doesn't support javascript.
loading
Confirmation of Safety of Titanium Wire in Sternotomy Closure, A Randomized Prospective Study.
Eraqi, Mohamed; Diab, Abdel Hannan; Matschke, Klaus; Alexiou, Konstantin.
Afiliación
  • Eraqi M; Klinikum Bayreuth GmbH, Bayreuth, Germany.
  • Diab AH; Department of Cardiac Surgery, Heart Center Dresden at the University Hospital Carl Gustav Carus, Dresden, Germany.
  • Matschke K; Department of Cardiac Surgery, Heart Center Dresden at the University Hospital Carl Gustav Carus, Dresden, Germany.
  • Alexiou K; Department of Cardiac Surgery, Heart Center Dresden at the University Hospital Carl Gustav Carus, Dresden, Germany.
Thorac Cardiovasc Surg ; 72(1): 70-76, 2024 01.
Article en En | MEDLINE | ID: mdl-36918153
BACKGROUND: There are many factors that are known to increase the risk of sternal wound infection (SWI); some studies have reported that nickel is a risk factor for SWI. Titanium wires have only been used as an alternative to steel wires in patients with known allergy to nickel. However, there is a paucity of literature regarding the safety of using titanium wires compared to that on the safety of steel wires for sternum closure after cardiac surgery. Therefore, this study aimed to demonstrate the noninferiority of titanium wires, even in patients without a known allergy. METHODS: A total of 322 patients who underwent elective full median sternotomy were randomly assigned to sternal closure either by titanium wires (n = 161) or by stainless steel wires. RESULTS: Fourteen patients had sternal instability, six (3.7%) patients in the titanium group and eight (5%) patients in the stainless steel group (p = 0.585). There was no statistically significant difference between both groups in terms of postoperative wound infection (p = 0.147). Patients in the titanium group experienced statistically significant lower postoperative pain than those in the stainless steel group (p = 0.024). The wire type was not an independent risk factor for SI, as shown by univariate and logistic regression analyses. CONCLUSION: Titanium wires are a good alternative and have been proven to be safe and effective for sternal closure. The surgeon should be aware of the possibility of developing an allergic reaction to the wires, especially in patients with previous multiple allergic histories.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Esternotomía / Hipersensibilidad Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Esternotomía / Hipersensibilidad Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Año: 2024 Tipo del documento: Article País de afiliación: Alemania