Your browser doesn't support javascript.
loading
A bedside swallowing screen for the identification of post-extubation dysphagia on the intensive care unit - validation of the Gugging Swallowing Screen (GUSS)-ICU.
Troll, Claudia; Trapl-Grundschober, Michaela; Teuschl, Yvonne; Cerrito, Adrien; Compte, Montserrat Gallego; Siegemund, Martin.
Afiliación
  • Troll C; Department of Therapies, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland. claudia.troll@usb.ch.
  • Trapl-Grundschober M; University Hospital Tulln, Alter Ziegelweg 10, 3430, Tulln an Der Donau, Austria.
  • Teuschl Y; Department for Clinical Neurosciences and Preventive Medicine, University for Continuing Education Krems, Dr.-Karl-Dorrek-Strasse 30, 3500, Krems, Austria.
  • Cerrito A; Bern University of Applied Sciences Health, Department of Health Professions, Murtenstrasse 10, 3008, Bern, Switzerland.
  • Compte MG; HNO Am Claraplatz, Claraplatz 1, 4058, Basel, Switzerland.
  • Siegemund M; Intensive Care Unit, Department Acute Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
BMC Anesthesiol ; 23(1): 122, 2023 04 13.
Article en En | MEDLINE | ID: mdl-37055724
PURPOSE: Screening for dysphagia at the intensive care unit (ICU) soon after extubation can prevent aspiration, pneumonia, lower mortality, and shorten re-feeding interval. This study aimed to modify the Gugging Swallowing Screen (GUSS), which was developed for acute stroke patients, and to validate it for extubated patients in the ICU. METHODS: In this prospective study, forty-five patients who had been intubated for at least 24 h were recruited consecutively at the earliest 24 h after extubation. The modified GUSS-ICU was performed twice by two speech and language therapists independently. Concurrently, gold standard the flexible endoscopic evaluation of swallowing (FEES) was performed by an otorhinolaryngologist. Measurements were conducted within a three-hour period; all testers were blinded to each other's results. RESULTS: According to FEES, 36 of 45 (80%) participants were diagnosed with dysphagia; 13 of those were severe, 12 moderate, and 11 mild. Compared to FEES, the GUSS-ICU predicted dysphagia well (area under the curve for the initial rater pair: 0.923, 95% CI 0.832-1.000 and 0.923, 95% CI 0.836 -1.000 for the second rater pair). The sensitivity was 91.7% (95% CI 77.5-98.3%) and 94.4% (95% CI 81.3-99.3%); the specificity was 88.9% (51.8-99.7%) and 66.7% (29.9-92.5%); the positive predictive values were 97.1% (83.8-99.5%) and 91.9% (81.7-96.6%), and the negative predictive values were 72.7% (46.8-89%) and 75% (41.9-92.6%) for the first and second rater pairs, respectively. Dysphagia severity classification according to FEES and GUSS-ICU correlated strongly (Spearman's rho: 0.61 for rater 1 and 0.60 for rater 2, p < 0.001). Agreement by all testers was good (Krippendorffs Alpha: 0.73). The interrater reliability showed good agreement (Cohen`s Kappa: 0.84, p < 0.001). CONCLUSION: The GUSS-ICU is a simple, reliable, and valid multi-consistency bedside swallowing screen to identify post-extubation dysphagia at the ICU. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04532398,31/08/2020.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Trastornos de Deglución Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Anesthesiol Año: 2023 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Trastornos de Deglución Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: BMC Anesthesiol Año: 2023 Tipo del documento: Article País de afiliación: Suiza