Static and dynamic validation of kinect for ergonomic postural analysis using electro-goniometers as a gold standard:A preliminary study.
Technol Health Care
; 31(6): 2107-2123, 2023.
Article
en En
| MEDLINE
| ID: mdl-37125584
BACKGROUND: Evaluation of the working postures and development of new techniques are paramount in reducing the awkward postures and occurrence of musculoskeletal disorders (MSDs). The Kinect sensor, a portable and cost-effective device, appears to be a promising alternative to study work postures. OBJECTIVE: The current study aimed to evaluate the validity of Kinect against the gold-standard instrument (electro-goniometers) for body joint angle measurements. METHODS: A unique software application was developed to measure the critical body joint angles for postural evaluation by using the Kinect's skeletal tracking feature. The body joint angle data of ten volunteers were measured simultaneously by both Kinect and electro-goniometers. The validation analysis was conducted in both static and dynamic domains of application. RESULTS: Minimal variation was observed between the two techniques, and the Kinect correlated well for upper-arm joint angles of 45∘, 60∘ and 90∘; lower-arm joint angles of 30∘, 45∘, 60∘, and 90∘; straight neck position, neck joint angle at maximum possible flexion; straight trunk position, trunk bend angle at full flexion. In dynamic analysis, four out of five ICC values were > 0.75 except for the upper arm. Discrepancies in the results indicated the disapproval of Kinect for only wrist measurements. CONCLUSION: The results of the static and dynamic studies gave a sufficient basis to consider the Kinect tool as an alternative to contemporary posture-based ergonomic evaluation methods.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Postura
/
Programas Informáticos
Límite:
Humans
Idioma:
En
Revista:
Technol Health Care
Asunto de la revista:
ENGENHARIA BIOMEDICA
/
SERVICOS DE SAUDE
Año:
2023
Tipo del documento:
Article
País de afiliación:
India