Is catheter-tissue contact force value important for ablation of ventricular arrhythmias originating from the left ventricular papillary muscles?
Baran, Jakub; Skrzynska-Kowalczyk, Martyna; Piotrowski, Roman; Sikorska, Agnieszka; Krynski, Tomasz; Kulakowski, Piotr.
Afiliación
  • Baran J; Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland.
  • Skrzynska-Kowalczyk M; Department of Internal Medicine and Cardiology University Clinical Center, Medical University of Warsaw, Warsaw, Poland.
  • Piotrowski R; Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland.
  • Sikorska A; Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland.
  • Krynski T; Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland.
  • Kulakowski P; Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland.
Front Cardiovasc Med ; 10: 1166810, 2023.
Article en En | MEDLINE | ID: mdl-37273878
Background: Good catheter-tissue contact is mandatory to create effective ablation lesions. The minimal contact force value for ablation of arrhythmias originating from the left ventricle is 8.0-10.0 grams but is not known for arrhythmias arising from papillary muscles. Purpose: To analyze contact force values during successful ablation procedures of arrhythmias originating from the left ventricular papillary muscles. Methods: 24 consecutive patients (mean age 57.9 ± 11.9 years, 16 males) underwent ablation of premature ventricular complexes originating from left ventricular papillary muscles with the use of CARTO electro-anatomical system and intracardiac echocardiography. Results: Acute complete abolition of ventricular ectopy was obtained in 23 (96%) patients. The fluoroscopy time was 3.9 ± 3.5 min and procedure duration - 114.8 ± 37.9 min. The mean contact force during successful ablations was 3.0 ± 1.1 grams and 3.18 ± 1.8 grams for antero-lateral and postero-medial papillary muscle, respectively (NS). The mean contact force during a single unsuccessful ablation was 3.0 grams. At control Holter ECG, the mean Ectopy Burden was Reduced in the Antero-Lateral Papillary Muscle Group from 18.0% ± 7.9% to 2.6% ± 2.9% (p = 0.005415) and in the Postero-Medial Papillary Muscle Group - from 34.8% ± 13.7%-1.7% ± 1.3% (p = 0.012694). During Median 27 (IQR: 17-34) Months of Follow-up There one Recurrence of Arrhythmia. Conclusion: The values of contact force for successful ablation of ventricular ectopy originating from the left ventricular papillary muscles may be much lower than those for ablation of other foci which questions the role of contact force measurement when ablating these arrhythmias.