Your browser doesn't support javascript.
loading
Feasibility, safety, and patient acceptability of electronic inspiratory muscle training in patients who require prolonged mechanical ventilation in the intensive care unit: A dual-centre observational study.
Nickels, Marc; Erwin, Katie; McMurray, Grant; Talbot, Richie; Strong, Mark; Krishnan, Anand; van Haren, Frank M P; Bissett, Bernie.
Afiliación
  • Nickels M; Department of Physiotherapy, Ipswich Hospital, Brisbane, Australia; Discipline of Physiotherapy, University of Canberra, Australia.
  • Erwin K; Physiotherapy Department, Canberra Hospital, Australia.
  • McMurray G; Physiotherapy Department, Princess Alexandra Hospital, Brisbane, Australia.
  • Talbot R; Discipline of Physiotherapy, University of Canberra, Australia.
  • Strong M; Physiotherapy Department, Princess Alexandra Hospital, Brisbane, Australia.
  • Krishnan A; Intensive Care Unit, Princess Alexandra Hospital, Brisbane, Australia.
  • van Haren FMP; Intensive Care Unit, St George Hospital, Sydney, Australia; College of Health and Medicine, Australian National University, Canberra, Australia.
  • Bissett B; Physiotherapy Department, Canberra Hospital, Australia; Discipline of Physiotherapy, University of Canberra, Australia. Electronic address: Bernie.Bissett@canberra.edu.au.
Aust Crit Care ; 37(3): 448-454, 2024 May.
Article en En | MEDLINE | ID: mdl-37321882
ABSTRACT

BACKGROUND:

Inspiratory muscle training (IMT) is an intervention that can be used to rehabilitate the respiratory muscle deconditioning experienced by patients with critical illness, requiring prolonged mechanical ventilation. Clinicians are currently using mechanical threshold IMT devices that have limited resistance ranges.

OBJECTIVES:

The objective of this study was to evaluate the safety, feasibility, and acceptability of using an electronic device to facilitate IMT with participants requiring prolonged mechanical ventilation.

METHOD:

A dual-centre observational cohort study, with convenience sampling, was conducted at two tertiary intensive care units. Daily training supervised by intensive care unit physiotherapists was completed with the electronic IMT device. A priori definitions for feasibility, safety, and acceptability were determined. Feasibility was defined as more than 80% of planned sessions completed. Safety was defined as no major adverse events and less than 3% minor adverse event rate, and acceptability was evaluated following the acceptability of intervention framework principles.

RESULTS:

Forty participants completed 197 electronic IMT treatment sessions. Electronic IMT was feasible, with 81% of planned sessions completed. There were 10% minor adverse events and no major adverse events. All the minor adverse events were transient without clinical consequences. All the participants who recalled completing electronic IMT sessions reported that the training was acceptable. Acceptability was demonstrated; over 85% of participants reported that electronic IMT was either helpful or beneficial and that electronic IMT assisted their recovery.

CONCLUSION:

Electronic IMT is feasible and acceptable to complete with critically ill participants who require prolonged mechanical ventilation. As all minor adverse events were transient without clinical consequences, electronic IMT can be considered a relatively safe intervention with patients who require prolonged mechanical ventilation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Respiración Artificial / Ejercicios Respiratorios Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Aust Crit Care Asunto de la revista: ENFERMAGEM / TERAPIA INTENSIVA Año: 2024 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Respiración Artificial / Ejercicios Respiratorios Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Aust Crit Care Asunto de la revista: ENFERMAGEM / TERAPIA INTENSIVA Año: 2024 Tipo del documento: Article País de afiliación: Australia