Transcatheter Aortic Valve Implantation: Addressing the Subsequent Risk of Permanent Pacemaker Implantation.
Lauten, Philipp; Costello-Boerrigter, Lisa C; Goebel, Björn; Gonzalez-Lopez, David; Schreiber, Matthias; Kuntze, Thomas; Al Jassem, Mahmoud; Lapp, Harald.
Afiliación
  • Lauten P; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Costello-Boerrigter LC; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Goebel B; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Gonzalez-Lopez D; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Schreiber M; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Kuntze T; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Al Jassem M; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
  • Lapp H; Department of Cardiology, Heart Center, Zentralklinik Bad Berka, Robert-Koch-Allee 9, 99437 Bad Berka, Germany.
J Cardiovasc Dev Dis ; 10(6)2023 May 24.
Article en En | MEDLINE | ID: mdl-37367395
ABSTRACT
Transcatheter aortic valve implantation (TAVI) is now a commonly used therapy in patients with severe aortic stenosis, even in those patients at low surgical risk. The indications for TAVI have broadened as the therapy has proven to be safe and effective. Most challenges associated with TAVI after its initial introduction have been impressively reduced; however, the possible need for post-TAVI permanent pacemaker implantation (PPI) secondary to conduction disturbances continues to be on the radar. Conduction abnormalities post-TAVI are always of concern given that the aortic valve lies in close proximity to critical components of the cardiac conduction system. This review will present a summary of noteworthy pre-and post-procedural conduction blocks, the best use of telemetry and ambulatory device monitoring to avoid unnecessary PPI or to recognize the need for late PPI due to delayed high-grade conduction blocks, predictors to identify those patients at greatest risk of requiring PPI, important CT measurements and considerations to optimize TAVI planning, and the utility of the MInimizing Depth According to the membranous Septum (MIDAS) technique and the cusp-overlap technique. It is stressed that careful membranous septal (MS) length measurement by MDCT during pre-TAVI planning is necessary to establish the optimal implantation depth before the procedure to reduce the risk of compression of the MS and consequent damage to the cardiac conduction system.