Your browser doesn't support javascript.
loading
Point-of-care diagnostics for rapid determination of prostate cancer biomarker sarcosine: application of disposable potentiometric sensor based on oxide-conductive polymer nanocomposite.
Yamani, Hend Z; Safwat, Nardine; Mahmoud, Amr M; Ayad, Miriam F; Abdel-Ghany, Maha F; Gomaa, Mohammed M.
Afiliación
  • Yamani HZ; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt.
  • Safwat N; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt. nardine.safwat2@pharma.asu.edu.eg.
  • Mahmoud AM; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, 11562, Egypt. amr.bekhet@pharma.cu.edu.eg.
  • Ayad MF; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt.
  • Abdel-Ghany MF; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt.
  • Gomaa MM; Solid State Physics Department, National Research Centre, Giza, 12622, Egypt.
Anal Bioanal Chem ; 415(22): 5451-5462, 2023 Sep.
Article en En | MEDLINE | ID: mdl-37389600
ABSTRACT
One of the most important reasons for an increased mortality rate of cancer is late diagnosis. Point-of-care (POC) diagnostic sensors can provide rapid and cost-effective diagnosis and monitoring of cancer biomarkers. Portable, disposable, and sensitive sarcosine solid-contact ion-selective potentiometric sensors (SC-ISEs) were fabricated as POC analyzers for the rapid determination of the prostate cancer biomarker sarcosine. Tungsten trioxide nanoparticles (WO3 NPs), polyaniline nanoparticles (PANI NPs), and PANI-WO3 nanocomposite were used as ion-to-electron transducers on screen-printed sensors. WO3 NPs and PANI-WO3 nanocomposite have not been investigated before as ion-to-electron transducer layers in potentiometric SC sensors. The designated sensors were characterized using SEM, XRD, FTIR, UV-VIS spectroscopy, and EIS. The inclusion of WO3 and PANI in SC sensors enhanced the transduction at the interface between the screen-printed SC and the ion-selective membrane, offering lower potential drift, a longer lifetime, shorter response time, and better sensitivity. The proposed sarcosine sensors exhibited Nernstian slopes over linear response ranges 10-3-10-7 M, 10-3-10-8 M, 10-5-10-9 M, and 10-7-10-12 M for control, WO3 NPs, PANI NPs, and PANI-WO3 nanocomposite-based sensors, respectively. From a comparative point of view between the four sensors, PANI-WO3 nanocomposite inclusion offered the lowest potential drift (0.5 mV h-1), the longest lifetime (4 months), and the best LOD (9.95 × 10-13 M). The proposed sensors were successfully applied to determine sarcosine as a potential prostate cancer biomarker in urine without prior sample treatment steps. The WHO ASSURED criteria for point-of-care diagnostics are met by the proposed sensors.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Nanocompuestos Tipo de estudio: Diagnostic_studies Límite: Humans / Male Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: Egipto

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Nanocompuestos Tipo de estudio: Diagnostic_studies Límite: Humans / Male Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: Egipto