Your browser doesn't support javascript.
loading
A double-tuned 1 H/31 P coil for rabbit heart metabolism detection at 3 T.
Quan, Zhiyan; Yang, Zhaoxia; Tang, Xiaocui; Fu, Caixia; Zhou, Xiaoyue; Huang, Lu; Xia, Liming; Zhang, Xiaotong.
Afiliación
  • Quan Z; The Interdisciplinary Institute of Neuroscience and Technology, School of Medicine, Zhejiang University, Hangzhou, China.
  • Yang Z; Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China.
  • Tang X; MOE Frontier Science Center for Brain Science and Brain-machine Integration, Zhejiang University, Hangzhou, China.
  • Fu C; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Zhou X; MOE Frontier Science Center for Brain Science and Brain-machine Integration, Zhejiang University, Hangzhou, China.
  • Huang L; Application Developments, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China.
  • Xia L; Siemens Healthineers Digital Technology (Shanghai) Co., Ltd., Shanghai, China.
  • Zhang X; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
NMR Biomed ; 37(2): e5049, 2024 Feb.
Article en En | MEDLINE | ID: mdl-37767723
ABSTRACT
Magnetic resonance imaging (MRI)/magnetic resonance spectroscopy (MRS) employing proton nuclear resonance has emerged as a pivotal modality in clinical diagnostics and fundamental research. Nonetheless, the scope of MRI/MRS extends beyond protons, encompassing nonproton nuclei that offer enhanced metabolic insights. A notable example is phosphorus-31 (31 P) MRS, which provides valuable information on energy metabolites within the skeletal muscle and cardiac tissues of individuals affected by diabetes. This study introduces a novel double-tuned coil tailored for 1 H and 31 P frequencies, specifically designed for investigating cardiac metabolism in rabbits. The proposed coil design incorporates a butterfly-like coil for 31 P transmission, a four-channel array for 31 P reception, and an eight-channel array for 1 H reception, all strategically arranged on a body-conformal elliptic cylinder. To assess the performance of the double-tuned coil, a comprehensive evaluation encompassing simulations and experimental investigations was conducted. The simulation results demonstrated that the proposed 31 P transmit design achieved acceptable homogeneity and exhibited comparable transmit efficiency on par with a band-pass birdcage coil. In vivo experiments further substantiated the coil's efficacy, revealing that the rabbit with experimentally induced diabetes exhibited a lower phosphocreatine/adenosine triphosphate ratio compared with its normal counterpart. These findings emphasize the potential of the proposed coil design as a promising tool for investigating the therapeutic effects of novel diabetes drugs within the context of animal experimentation. Its capability to provide detailed metabolic information establishes it as an indispensable asset within this realm of research.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Diabetes Mellitus Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Diabetes Mellitus Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2024 Tipo del documento: Article País de afiliación: China