Optimization of Gradient-Echo Echo-Planar Imaging for T2* Contrast in the Brain at 0.5 T.
Halder, Arjama; Harris, Chad T; Wiens, Curtis N; Soddu, Andrea; Chronik, Blaine A.
Afiliación
  • Halder A; Department of Medical Biophysics, Western University, London, ON N6A 3K7, Canada.
  • Harris CT; Synaptive Medical, Toronto, ON M5V 3B1, Canada.
  • Wiens CN; Synaptive Medical, Toronto, ON M5V 3B1, Canada.
  • Soddu A; Western Institute for Neuroscience, Physics and Astronomy, Western University, London, ON N6A 3K7, Canada.
  • Chronik BA; Department of Medical Biophysics, Western University, London, ON N6A 3K7, Canada.
Sensors (Basel) ; 23(20)2023 Oct 12.
Article en En | MEDLINE | ID: mdl-37896521
ABSTRACT
Gradient-recalled echo (GRE) echo-planar imaging (EPI) is an efficient MRI pulse sequence that is commonly used for several enticing applications, including functional MRI (fMRI), susceptibility-weighted imaging (SWI), and proton resonance frequency (PRF) thermometry. These applications are typically not performed in the mid-field (<1 T) as longer T2* and lower polarization present significant challenges. However, recent developments of mid-field scanners equipped with high-performance gradient sets offer the possibility to re-evaluate the feasibility of these applications. The paper introduces a metric "T2* contrast efficiency" for this evaluation, which minimizes dead time in the EPI sequence while maximizing T2* contrast so that the temporal and pseudo signal-to-noise ratios (SNRs) can be attained, which could be used to quantify experimental parameters for future fMRI experiments in the mid-field. To guide the optimization, T2* measurements of the cortical gray matter are conducted, focusing on specific regions of interest (ROIs). Temporal and pseudo SNR are calculated with the measured time-series EPI data to observe the echo times at which the maximum T2* contrast efficiency is achieved. T2* for a specific cortical ROI is reported at 0.5 T. The results suggest the optimized echo time for the EPI protocols is shorter than the effective T2* of that region. The effective reduction of dead time prior to the echo train is feasible with an optimized EPI protocol, which will increase the overall scan efficiency for several EPI-based applications at 0.5 T.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Imagen Eco-Planar Idioma: En Revista: Sensors (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Imagen Eco-Planar Idioma: En Revista: Sensors (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Canadá