Design and first-round commissioning result of the SASE beamline at the Shanghai Soft X-ray FEL facility.
Xue, Chaofan; Guo, Zhi; Liu, Haigang; Chen, Jiahua; Tong, Yajun; Fan, Jiadong; Jiang, Huaidong; Liu, Zhi; Zhang, Ximing; Tai, Renzhong.
Afiliación
  • Xue C; Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
  • Guo Z; Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
  • Liu H; Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
  • Chen J; Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
  • Tong Y; ShanghaiTech University, Shanghai 201210, People's Republic of China.
  • Fan J; ShanghaiTech University, Shanghai 201210, People's Republic of China.
  • Jiang H; ShanghaiTech University, Shanghai 201210, People's Republic of China.
  • Liu Z; ShanghaiTech University, Shanghai 201210, People's Republic of China.
  • Zhang X; Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
  • Tai R; Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
J Synchrotron Radiat ; 31(Pt 1): 177-185, 2024 Jan 01.
Article en En | MEDLINE | ID: mdl-37971956
ABSTRACT
The Shanghai Soft X-ray Free-Electron Laser (SXFEL) is the first X-ray free-electron laser facility in China. The SASE beamline, which consists of a pink-beam branch and a mono-beam branch, is one of the two beamlines in the Phase-I construction. The pink-beam branch opened for users in 2023 after successful first-round beamline commissioning. In this paper, the design of the beamline is presented and the performance of the pink-beam branch is reported. The measured energy-resolving power of the online spectrometer is over 6000 @ 400 eV. The focusing spot size of the pink beam is less than 3 µm in both the horizontal and vertical at the endstation.