Your browser doesn't support javascript.
loading
Effects of storage temperature and time on metabolite profiles measured in dried blood spots, dried blood microsamplers, and plasma.
Petrick, Lauren M; Niedzwiecki, Megan M; Dolios, Georgia; Guan, Haibin; Tu, Peijun; Wright, Robert O; Wright, Rosalind J.
Afiliación
  • Petrick LM; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA; The Institute for Exposomics Research, Icahn School of Medicine at Mount Sinai, New York, NY, USA; The Bert Strassburger Metabolic Center, Sheba Medical Center, Tel-Hashomer, Israel. E
  • Niedzwiecki MM; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA; The Institute for Exposomics Research, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Dolios G; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Guan H; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Tu P; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Wright RO; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA; The Institute for Exposomics Research, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Wright RJ; Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, NY, USA; The Institute for Exposomics Research, Icahn School of Medicine at Mount Sinai, New York, NY, USA; Department of Pediatrics, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Sci Total Environ ; 912: 169383, 2024 Feb 20.
Article en En | MEDLINE | ID: mdl-38101622
ABSTRACT
The practical advantages of capillary whole blood collection over venipuncture plasma collection for human exposome research are well known. However, before epidemiologists, clinicians, and public health researchers employ these microvolume sample collections, a rigorous evaluation of pre-analytical storage conditions is needed to develop protocols that maximize sample stability and reliability over time. Therefore, we performed a controlled experiment of dried whole blood collected on 10 µL Mitra microsamplers (DBM), 5-mm punches of whole blood from a dried blood spot (DBS), and 10 µL of plasma, and evaluated the effects of storage conditions at 4 °C, -20 °C, or -80 °C for up to 6 months on the resulting metabolite profiles measured with untargeted liquid chromatography-high resolution mass spectrometry (LC-HRMS). At -80 °C storage conditions, metabolite profiles from DBS, DBM, and plasma showed similar stability. While DBS and DBM metabolite profiles remained similarly stable at -20 °C storage, plasma profiles showed decreased stability at -20 °C compared to -80 °C storage. At refrigerated temperatures (4 °C), metabolite profiles collected on DBM were more stable than plasma or DBS, particularly for lipid classes. These results inform robust capillary blood sample storage protocols for DBM and DBS at potentially warmer temperatures than -80 °C, which may facilitate blood collections for populations outside of a clinical setting.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Plasma / Manejo de Especímenes Límite: Humans Idioma: En Revista: Sci Total Environ Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Plasma / Manejo de Especímenes Límite: Humans Idioma: En Revista: Sci Total Environ Año: 2024 Tipo del documento: Article