Your browser doesn't support javascript.
loading
Non-neotissue constituents as underestimated confounders in the assessment of tissue engineered constructs by near-infrared spectroscopy.
Elkadi, Omar Anwar; Abinzano, Florencia; Nippolainen, Ervin; González, Ona Bach; Levato, Riccardo; Malda, Jos; Afara, Isaac O.
Afiliación
  • Elkadi OA; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
  • Abinzano F; Department of Orthopedics, University Medical Center Utrecht, Utrecht University, 3584 CX, Utrecht, the Netherlands.
  • Nippolainen E; Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
  • González OB; Department of Orthopedics, University Medical Center Utrecht, Utrecht University, 3584 CX, Utrecht, the Netherlands.
  • Levato R; Department of Orthopedics, University Medical Center Utrecht, Utrecht University, 3584 CX, Utrecht, the Netherlands.
  • Malda J; Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, 3584 CT, Utrecht, the Netherlands.
  • Afara IO; Department of Orthopedics, University Medical Center Utrecht, Utrecht University, 3584 CX, Utrecht, the Netherlands.
Mater Today Bio ; 24: 100879, 2024 Feb.
Article en En | MEDLINE | ID: mdl-38130429
ABSTRACT
Non-destructive assessments are required for the quality control of tissue-engineered constructs and the optimization of the tissue culture process. Near-infrared (NIR) spectroscopy coupled with machine learning (ML) provides a promising approach for such assessment. However, due to its nonspecific nature, each spectrum incorporates information on both neotissue and non-neotissue constituents of the construct; the effect of these constituents on the NIR-based assessments of tissue-engineered constructs has been overlooked in previous studies. This study investigates the effect of scaffolds, growth factors, and buffers on NIR-based assessments of tissue-engineered constructs. To determine if these non-neotissue constituents have a measurable effect on the NIR spectra of the constructs that can introduce bias in their assessment, nine ML algorithms were evaluated in classifying the NIR spectra of engineered cartilage according to the scaffold used to prepare the constructs, the growth factors added to the culture media, and the buffers used for storing the constructs. The effect of controlling for these constituents was also evaluated using controlled and uncontrolled NIR-based ML models for predicting tissue maturity as an example of neotissue-related properties of interest. Samples used in this study were prepared using norbornene-modified hyaluronic acid scaffolds with or without the conjugation of an N-cadherin mimetic peptide. Selected samples were supplemented with transforming growth factor-beta1 or bone morphogenetic protein-9 growth factor. Some samples were frozen in cell lysis buffer, while the remaining samples were frozen in PBS until required for NIR analysis. The ML models for classifying the spectra of the constructs according to the four constituents exhibited high to fair performances, with F1 scores ranging from 0.9 to 0.52. Moreover, controlling for the four constituents significantly improved the performance of the models for predicting tissue maturity, with improvement in F1 scores ranging from 0.09 to 0.77. In conclusion, non-neotissue constituents have measurable effects on the NIR spectra of tissue-engineered constructs that can be detected by ML algorithms and introduce bias in the assessment of the constructs by NIR spectroscopy. Therefore, controlling for these constituents is necessary for reliable NIR-based assessments of tissue-engineered constructs.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Mater Today Bio Año: 2024 Tipo del documento: Article País de afiliación: Finlandia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Mater Today Bio Año: 2024 Tipo del documento: Article País de afiliación: Finlandia