Your browser doesn't support javascript.
loading
Single Ventricular Assist Device Care and Outcomes for Failed Stage I Palliation: A Single-Center Decade of Experience.
Kulp, Blaire E; Khan, Marium N; Gazit, Avihu Z; Eghtesady, Pirooz; Scheel, Janet N; Said, Ahmed S; Rabinowitz, Edon J.
Afiliación
  • Kulp BE; From the Washington University School of Medicine in St Louis Department of Pediatrics and St Louis Children's Hospital, St Louis, MO.
  • Khan MN; From the Washington University School of Medicine in St Louis Department of Pediatrics and St Louis Children's Hospital, St Louis, MO.
  • Gazit AZ; Division of Pediatric Critical Care Medicine, St Louis, MO.
  • Eghtesady P; From the Washington University School of Medicine in St Louis Department of Pediatrics and St Louis Children's Hospital, St Louis, MO.
  • Scheel JN; Division of Pediatric Critical Care Medicine, St Louis, MO.
  • Said AS; Division of Pediatric Cardiology, St Louis, MO.
  • Rabinowitz EJ; From the Washington University School of Medicine in St Louis Department of Pediatrics and St Louis Children's Hospital, St Louis, MO.
ASAIO J ; 70(6): 517-526, 2024 06 01.
Article en En | MEDLINE | ID: mdl-38346282
ABSTRACT
Single ventricular assist device (SVAD) use before and after stage I palliation (S1P) is increasing with limited data on outcomes. To address this knowledge gap, we conducted a single-center retrospective review to assess pre- and post-SVAD clinical status, complications, and outcomes. We leveraged a granular, longitudinal, local database that captures end-organ support, procedural interventions, hematologic events, laboratory data, and antithrombotic strategy. We identified 25 patients between 2013 and 2023 implanted at median age of 53 days (interquartile range [IQR] = 16-130); 80% had systemic right ventricles and underwent S1P. Median SVAD days were 54 (IQR = 29-86), and 40% were implanted directly from ECMO. Compared to preimplant, there was a significant reduction in inotrope use ( p = 0.013) and improved weight gain ( p = 0.008) post-SVAD. Complications were frequent including bleeding (80%), stroke (40%), acute kidney injury (AKI) (40%), infection (36%), and unanticipated catheterization (56%). Patients with in-hospital mortality had significantly more bleeding complications ( p = 0.02) and were more likely to have had Blalock-Thomas-Taussig shunts pre-SVAD ( p = 0.028). Survival to 1 year postexplant was 40% and included three recovered and explanted patients. At 1 year posttransplant, all survivors have technology dependence or neurologic injury. This study highlights the clinical outcomes and ongoing support required for successful SVAD use in failed single-ventricle physiology before or after S1P.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cuidados Paliativos / Corazón Auxiliar Límite: Female / Humans / Infant / Male / Newborn Idioma: En Revista: ASAIO J Asunto de la revista: TRANSPLANTE Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cuidados Paliativos / Corazón Auxiliar Límite: Female / Humans / Infant / Male / Newborn Idioma: En Revista: ASAIO J Asunto de la revista: TRANSPLANTE Año: 2024 Tipo del documento: Article