Your browser doesn't support javascript.
loading
Characterization of Concanavalin A-based lectin sorbents for the extraction of the human chorionic gonadotropin glycoforms prior to analysis by nano liquid chromatography-high resolution mass spectrometry.
Goumenou, Anastasia; Chendo, Christophe; Combès, Audrey; Fournier, Thierry; Pichon, Valérie; Delaunay, Nathalie.
Afiliación
  • Goumenou A; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, Chemistry, Biology and Innovation (CBI) UMR 8231, ESPCI Paris PSL, CNRS, PSL Research University, Paris, France.
  • Chendo C; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, Chemistry, Biology and Innovation (CBI) UMR 8231, ESPCI Paris PSL, CNRS, PSL Research University, Paris, France.
  • Combès A; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, Chemistry, Biology and Innovation (CBI) UMR 8231, ESPCI Paris PSL, CNRS, PSL Research University, Paris, France.
  • Fournier T; Université Paris Cité, INSERM, "Pathophysiology & Pharmacotoxicology of the Human Placenta, pre & postnatal Microbiota", 3PHM, F-75006 Paris, France.
  • Pichon V; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, Chemistry, Biology and Innovation (CBI) UMR 8231, ESPCI Paris PSL, CNRS, PSL Research University, Paris, France; Sorbonne Université, Paris, France.
  • Delaunay N; Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, Chemistry, Biology and Innovation (CBI) UMR 8231, ESPCI Paris PSL, CNRS, PSL Research University, Paris, France. Electronic address: nathalie.delaunay@espci.fr.
J Pharm Biomed Anal ; 242: 116022, 2024 May 15.
Article en En | MEDLINE | ID: mdl-38354538
ABSTRACT
Human chorionic gonadotropin (hCG) is constituted of the hCGα and hCGß subunits and is a highly glycosylated protein. Affinity supports based on immobilized Concanavalin A (Con A) lectin were used in solid phase extraction (SPE) to fractionate the hCG glycoforms according to their glycosylation state. For the first time, the lectin SPE fractions were off-line analysed by a nano liquid chromatography - high-resolution mass spectrometry (nanoLC-HRMS) method keeping the glycoforms intact. For this, home-made Con A sorbents were prepared by immobilizing lectin on Sepharose with a mean grafting yield of 98.2% (relative standard deviation (RSD) of 3.5%, n = 15). A capacity of about 100 µg of purified urinary hCG (uhCG) per ml of sorbent, grafted with a density of 10 mg of Con A per ml, was estimated. Average extraction yields of around 60% for both hCGα and hCGß glycoforms were obtained after optimization of the extraction protocol. Intra- and inter-assay evaluation led to average RSD values of around 10%, indicating a repeatable extraction procedure. Similar results were obtained with commercial Con A-based sorbents but only after their 3rd use or after an extensive pre-conditioning step. Finally, the Con A SPE led to the fractionation of some glycoforms of uhCG, allowing the detection of an hCGα glycoform with two tetra-antennary N-glycans that couldn't be detected by direct analysis in nanoLC-HRMS without Con A SPE. Regarding a recombinant hCG, a fractionation was also observed leading to the detection of unretained hCGα glycoforms with tri-antennary N-glycans. Therefore, the combination of lectin SPE with intact protein analysis by nanoLC-HRMS can contribute to a more detailed glycosylation characterization of the hCG protein.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Gonadotropina Coriónica / Lectinas Límite: Humans Idioma: En Revista: J Pharm Biomed Anal Año: 2024 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Gonadotropina Coriónica / Lectinas Límite: Humans Idioma: En Revista: J Pharm Biomed Anal Año: 2024 Tipo del documento: Article País de afiliación: Francia