Your browser doesn't support javascript.
loading
Real-world outcomes of Omnipod DASH system use in people with type 1 diabetes: Evidence from the Association of British Clinical Diabetologists (ABCD) study.
Liarakos, Alexandros L; Hasan, Nebras; Crabtree, Thomas S J; Leelarathna, Lalantha; Hammond, Peter; Hussain, Sufyan; Haq, Masud; Aslam, Aisha; Gatdula, Erneda; Gibb, Fraser W; Lumb, Alistair; Bull, Kirsty; Chinnasamy, Eswari; Carrieri, Giorgio; Williams, David M; Choudhary, Pratik; Ryder, Robert E J; Wilmot, Emma G.
Afiliación
  • Liarakos AL; Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK.
  • Hasan N; Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK.
  • Crabtree TSJ; Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK.
  • Leelarathna L; Diabetes, Endocrinology and Metabolism Center, Manchester University NHS Foundation Trust, Manchester Royal Infirmary, Manchester, UK.
  • Hammond P; Department of Diabetes and Endocrinology, Harrogate and District NHS Trust, Harrogate, UK.
  • Hussain S; Department of Diabetes and Endocrinology, Guy's and St. Thomas' NHS Foundation Trust, London, UK; Department of Diabetes, School of Cardiovascular, Metabolic Medicine and Sciences, King's College London, London, UK.
  • Haq M; Maidstone & Tunbridge Wells NHS Trust, Tunbridge Wells Hospital, Royal Tunbridge Wells, UK.
  • Aslam A; Diabetes, Endocrinology and Metabolism Center, Manchester University NHS Foundation Trust, Manchester Royal Infirmary, Manchester, UK.
  • Gatdula E; Cardiff and Vale University Health Board, University Hospital of Llandough, Llandough, UK.
  • Gibb FW; Edinburgh Centre for Endocrinology & Diabetes, Royal Infirmary of Edinburgh, Edinburgh, UK; University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK.
  • Lumb A; Oxford Centre for Diabetes, Endocrinology and Metabolism, Churchill Hospital, Oxford, UK; NIHR Oxford Biomedical Research Centre, Oxford, UK.
  • Bull K; Stockport Foundation Trust, Stepping Hill Hospital, Stockport, UK.
  • Chinnasamy E; Kingston Hospital NHS Foundation Trust, Kingston Hospital, Surrey, UK.
  • Carrieri G; Somerset NHS Foundation Trust, Musgrove Park Hospital, Taunton, UK.
  • Williams DM; Swansea Bay University Health Board, Morriston Hospital, Swansea, UK.
  • Choudhary P; Leicester Diabetes Center, University Hospitals of Leicester, Leicester, UK; Diabetes Research Center, College of Health Sciences, University of Leicester, Leicester, UK.
  • Ryder REJ; Department of Diabetes and Endocrinology, City Hospital, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK.
  • Wilmot EG; Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK. Electronic address: emma.wilmot@nottingham.ac.uk.
Diabetes Res Clin Pract ; 209: 111597, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38417535
ABSTRACT

AIMS:

To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System.

METHODS:

Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed. Individuals were classified to "new-to-pump" (switched from multiple daily injections) and "established-on-pump" (switched from a tethered insulin pump) groups.

RESULTS:

276 individuals from 11 centers [66.7 % female; 92 % White British; median age 41 years (IQR 20-50); diabetes duration 20 years (IQR 11-31); 49.3 % within "new-to-pump" group] were included. Baseline HbA1c was 8.0 ± 1.3 % (64 ± 14 mmol/mol). At follow-up [3 years (IQR 1.5-3.2)], HbA1c reduced by 0.3 % [(3 mmol/mol); p = 0.002] across the total population, 0.4 % [(5 mmol/mol); p = 0.001] in those "new-to-pump" and remained unchanged in those "established-on-pump". TDD decreased in the "new-to-pump" cohort (baseline44.9 ± 21.0units vs follow-up38.1 ± 15.4units, p = 0.002). Of those asked, 141/143 (98.6 %) stated Omnipod DASH had a positive impact on quality of life.

CONCLUSIONS:

Omnipod DASH was associated with improvements in HbA1c in PwT1D "new-to-pump" and maintained previous HbA1c levels in those "established-on-pump". User satisfaction in all groups and TDD reduction in those "new-to-pump" were reported.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diabetes Mellitus Tipo 1 Límite: Adult / Female / Humans / Male Idioma: En Revista: Diabetes Res Clin Pract Asunto de la revista: ENDOCRINOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diabetes Mellitus Tipo 1 Límite: Adult / Female / Humans / Male Idioma: En Revista: Diabetes Res Clin Pract Asunto de la revista: ENDOCRINOLOGIA Año: 2024 Tipo del documento: Article