Your browser doesn't support javascript.
loading
Biometric description of 34 589 eyes undergoing cataract surgery: sex differences.
Jiménez-García, Marta; Segura-Calvo, Francisco J; Puzo, Martín; Castro-Alonso, Francisco J.
Afiliación
  • Jiménez-García M; From the GIMSO, Institute for Health Research Aragón, Hospital Universitario Miguel Servet, Zaragoza, Spain (Jiménez-García, Segura-Calvo, Puzo, Castro-Alonso); UFR, Department of Ophthalmology, University Hospital Miguel Servet, Zaragoza, Spain (Jiménez-García, Segura-Calvo, Puzo, Castro-Alonso); ARCCA, Department of Ophthalmology, Hospital Nuestra Señora de Gracia, Zaragoza, Spain (Jiménez-García, Segura-Calvo, Puzo, Castro-Alonso); Surgery Department, Ophthalmology Area, University of Zaragoz
J Cataract Refract Surg ; 50(7): 668-675, 2024 Jul 01.
Article en En | MEDLINE | ID: mdl-38446495
ABSTRACT

PURPOSE:

To describe gender differences in the biometric parameters of a large sample of patients with cataract. Cataract surgery has evolved from a vision restoration to a refractive procedure, and population-based studies are vital to optimize normative databases and postsurgical outcomes.

SETTING:

Miguel Servet University Hospital, Zaragoza, Spain.

DESIGN:

Retrospective single-center observational study.

METHODS:

The study included 34 589 eyes (20 004 patients with cataract). Biometric data were obtained from IOL Master 700 and Pentacam HR. Linear mixed models were used to account for intereye correlation. HofferQST formula was used to calculate the hypothetical distribution of intraocular lens (IOL) power (arbitrary lens; A = 119.2).

RESULTS:

Most biometric variables showed significant differences between sexes ( P < .0001), such as 0.53 mm shorter eyes found in females, of which 0.16 mm are explained by shorter aqueous depth. Steeper anterior keratometries (∼0.75 diopter [D]) were found in women, to end up in no difference on anterior astigmatism magnitude, but different orientation ( P < .0001). The distribution of IOL power differed between sexes ( P < .001), with the interquartile range shifting 1 D toward more powerful lenses in women and odds ratio (power >26 D) = 2.26, P < .0001 (Fisher).

CONCLUSIONS:

Large sample size studies provide smaller margin of error, higher power, and controlled risk of reporting false (negative or positive) findings. Highly significant differences between sexes in ocular biometry were found; this supports the idea that including sex as a parameter in IOL calculation should be explored and may improve results. In addition, the distribution of IOL powers was provided, which may be useful for manufacturers and hospital stock planning.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Biometría / Lentes Intraoculares Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Cataract Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Biometría / Lentes Intraoculares Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Cataract Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 2024 Tipo del documento: Article