Your browser doesn't support javascript.
loading
Alix-normalized exosomal programmed death-ligand 1 analysis in urine enables precision monitoring of urothelial cancer.
Woo, Hyun-Kyung; Park, Juhee; Kim, Kyung Hwan; Ku, Ja Yoon; Ha, Hong Koo; Cho, Yoon-Kyoung.
Afiliación
  • Woo HK; Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan, South Korea.
  • Park J; Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, South Korea.
  • Kim KH; Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan, South Korea.
  • Ku JY; Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea.
  • Ha HK; Department of Urology, Pusan National University Hospital, College of Medicine, Pusan National University, Busan, South Korea.
  • Cho YK; Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea.
Cancer Sci ; 115(5): 1602-1610, 2024 May.
Article en En | MEDLINE | ID: mdl-38480462
ABSTRACT
Anti-programmed death-ligand 1 (PD-L1) Ab-based therapies have demonstrated potential for treating metastatic urothelial cancer with high PD-L1 expression. Urinary exosomes are promising biomarkers for liquid biopsy, but urine's high variability requires normalization for accurate analysis. This study proposes using the PD-L1/Alix ratio to normalize exosomal PD-L1 signal intensity with Alix, an internal exosomal protein less susceptible to heterogeneity concerns than surface protein markers. Extracellular vesicles were isolated using ExoDisc and characterized using various methods, including ExoView to analyze tetraspanins, PD-L1, and Alix on individual exosomes. On-disc ELISA was used to evaluate PD-L1 and Alix-normalized PD-L1 in 15 urothelial cancer patients during the initial treatment cycle with Tecentriq. Results showed that Alix signal range was relatively uniform, whereas tetraspanin marker intensity varied for individual exosome particles. On-disc ELISA was more reliable for detecting exosomal PD-L1 expression than standard plate ELISA-based measurement. Using exosomal Alix expression for normalization is a more reliable approach than conventional methods for monitoring patient status. Overall, the study provides a practical and reliable method for detecting exosomal PD-L1 in urine samples from patients with urothelial cancer.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Biomarcadores de Tumor / Exosomas / Antígeno B7-H1 Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Cancer Sci Año: 2024 Tipo del documento: Article País de afiliación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Biomarcadores de Tumor / Exosomas / Antígeno B7-H1 Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Cancer Sci Año: 2024 Tipo del documento: Article País de afiliación: Corea del Sur